126
IBM® Netfinity® 5100 User’s Reference
POST
164
A change in the memory configuration occurred. This message might appear after you
add or remove memory.
Note:
The server can be used with decreased memory capacity.
Action:
1. If POST error message 289 also occurred, follow the instructions for
that error message first.
2. If you just installed or removed memory, run the Configuration/Setup
Utility program; then, exit, saving the new configuration settings.
If the message appears again, shutdown the server, reseat the memory
modules, and restart the server.
3. If the problem persists, check to see if the system has isolated the
problem to a memory module:
•
If the System Error light on the operator information panel is on,
check to see if the MEM LED on the diagnostic LED panel is on.
If it is on, check the DIMM Error LEDs next to the memory
sockets. If a DIMM Error LED is on, run the diagnostic program
for the memory.
— If the tests fail, replace the DIMM. If the problem persists
after you replace the DIMM, call for service.
— If the memory tests do not fail, call for service.
•
If no error LED is on, the error logs in the Configuration/Setup
Utility program might provide additional information on the
memory error.
If the problem persists, call for service.
175
A vital product data (VPD) error occurred.
Action:
Call for service.
176
177
178
A security hardware error occurred.
Action:
Check for indications that someone has tampered with the server. If no one
has tampered with the server, call for service.
184
The power-on password information stored in your server has been removed.
Action:
From the Configuration/Setup Utility program main menu, select System
Security.
Then, follow the instructions on the screen.
If this information cannot be restored, call for service.
185
A power failure damaged the stored information about the drive-startup sequence.
Action:
From the Configuration/Setup Utility program main menu, select Start
Options
; then, follow the instructions on the screen.
If this information cannot be restored, call for service.
186
A system board or hardware error occurred.
Action:
Call for service.
187
The VPD serial number is not set.
Action:
The system serial number is set in the VPD EEPROM at the time of
manufacturing. If the system board has been replaced, the system serial
number will be invalid and should be set. From the main menu of the
Configuration/Setup Utility program, select System Information, then
select Product Data. If the problem persists, call for service.
POST message
Description
Table 14. POST error messages
Содержание 5100
Страница 1: ...IBM IBM Netfinity 5100 User s Reference SC19 K080 70...
Страница 2: ......
Страница 3: ...IBM IBM Netfinity 5100 User s Reference SC19 K080 70...
Страница 8: ...IBM Netfinity 5100 User s Reference...
Страница 14: ...xii IBM Netfinity 5100 User s Reference...
Страница 24: ...10 IBM Netfinity 5100 User s Reference Operator information panel...
Страница 36: ...22 IBM Netfinity 5100 User s Reference Using the SCSISelect utility program...
Страница 74: ...60 IBM Netfinity 5100 User s Reference Netfinity Manager...
Страница 190: ...176 IBM Netfinity 5100 User s Reference Getting help service and information...
Страница 210: ...196 IBM Netfinity 5100 User s Reference Product warranties and notices...
Страница 213: ......