2.
Plan where you will place the units. Place the larger and heavier units in the lower part of the rack.
These expansion units are four Electronic Industries Alliance (EIA) units high. The rack contains three
mounting holes for each EIA unit of height. Each of these units therefore is 7 in. (177.8 mm) high and
covers 12 mounting holes in the rack.
3.
Remove the filler panels to allow access to the inside of the rack enclosure where you plan to place
the unit.
4.
Remove the front and back rack doors if necessary.
5.
Use one of these procedures to mark the location:
a.
If you have a rack-mounting template see “Marking the location using rack-mounting template”
on page 95.
b.
If you do not have a rack-mounting template, follow the instructions for marking the location
without a template see “Marking the location without a rack-mounting template” on page 95.
Figure 95. Removing the filler panels
94
Installing into a rack
Содержание 0551
Страница 1: ...Power Systems Rack rack features and installing systems or expansion units into a rack ...
Страница 2: ......
Страница 3: ...Power Systems Rack rack features and installing systems or expansion units into a rack ...
Страница 8: ...vi Installing into a rack ...
Страница 12: ...2 Installing into a rack ...
Страница 34: ...24 Installing into a rack ...
Страница 118: ...108 Installing into a rack ...
Страница 126: ...116 Installing into a rack ...
Страница 130: ...120 Installing into a rack ...
Страница 136: ...4 Remove the latch bracket from the system unit Figure 124 Removing the retaining screws 126 Installing into a rack ...
Страница 148: ...138 Installing into a rack ...
Страница 164: ...154 Installing into a rack ...
Страница 174: ...3 Close the front rack door 164 Installing into a rack ...
Страница 181: ......
Страница 182: ... Printed in USA ...