background image

AS/400e 170 or 250

0367 Operations Console

and 0381 Remote Control

Panel Cable Instruction

Version 4

SENG-0367-04

Содержание 0367

Страница 1: ...AS 400e 170 or 250 0367 Operations Console and 0381 Remote Control Panel Cable Instruction V ersion 4 SENG 0367 04...

Страница 2: ......

Страница 3: ...AS 400e 170 or 250 0367 Operations Console and 0381 Remote Control Panel Cable Instruction V ersion 4 SENG 0367 04...

Страница 4: ...d the Notices on page 23 Fifth Edition July 2000 This edition applies only to reduced instructions set computer RISC systems Copyright International Business Machines Corporation 1998 2000 All rights...

Страница 5: ...f possible disconnect all power cords from the existing system before you add or remove a device RSFTD203 DANGER To prevent a possible electrical shock during an electrical storm do not connect or dis...

Страница 6: ...rmation on each battery type where applicable Battery Return Program In the United States IBM has established a collection process for reuse recycling or proper disposal of used IBM batteries and batt...

Страница 7: ...hen you install the Operations Console cable Feature 0367 and the Remote Control Panel cable Feature 0381 you may receive instructions for each feature The instructions are identical use only one set...

Страница 8: ...of the following cables v Operations Console Cable part number 97H7557 v Remote Control Cable part number 97H7591 9600 baud modem minimum if the LCS will receive calls from an RCS or this workstation...

Страница 9: ...tall Dial Up Networking later in this document __ 7 Click on Cancel Note If you are using either COM3 or COM4 be sure that the addresses and the IRQ settings do not conflict with other hardware resour...

Страница 10: ...position C08 Yes No Go to step 17 on page 6 __ 11 Disconnect the system unit console cable Figure 2 on page 5 that is connected to Port 1 right connector Disconnect the other end of the cable from yo...

Страница 11: ...Port 1 __ 13 Find the new cable part number 97H7557 and label that cable C08 Port 0 __ 14 Attention To avoid bending the pins carefully align the cable connectors with the connectors or ports on the c...

Страница 12: ..._ 19 Connect the other end of the cable to an available serial port on your system unit console PC Note If the cable does not correctly match the connector on the personal computer you may use a 9 to...

Страница 13: ...n your Operations Console PC __ 3 Click on Start __ 4 Click on Settings __ 5 Click on Control Panel __ 6 Click on Add Remove Programs __ 7 Is IBM AS 400 Client Access for Windows 95 NT shown Yes No Cl...

Страница 14: ...atically start the setup program No Yes Go to step 18 __ 14 Click on Start __ 15 Click on Run __ 16 Enter d setup where d is the CD ROM drive letter The Setup window appears after a few seconds To con...

Страница 15: ...version may also have a letter after that number Click on Cancel __ 2 Click on Add Remove Programs __ 3 Is your version 4 00 950 or 4 00 950a Yes No Do the following a Click on Windows Setup b Click...

Страница 16: ...n Have disk __ c Click on Browse __ d If Locate File dialog message appears indicating A is not accessible click on Cancel __ e In the Drives section select the drive where you installed Client Access...

Страница 17: ...ar in the Function Data display No Yes Go to step 3g on page 12 __ b Is the Function Data display lit Yes No Before calling your hardware service representative do the following v Confirm that the ele...

Страница 18: ...nd continue PC Setup __ 4 Open the Operations Console icon by doing the following __ a Start __ b Programs __ c IBM AS 400 Client Access __ d AS 400 Operations Console __ 5 Select Local Controlling Sy...

Страница 19: ...ystem unit will be using a twinaxial console use the Remote Control Panel to power on the AS 400 Sign on the DST display In the User field type QSECOFR In the Password field type QSECOFR The installat...

Страница 20: ...key __ 30 Wait for the power light to turn off __ 31 Go to Completing the Installation on page 20 Installing Windows NT Console Support __ 1 To determine if you have Remote Access Service RAS install...

Страница 21: ...n click on Next when asked to choose the network adapter without selecting the adapter When the Add RAS Device window appears continue with step 13 __ 8 Click on Services __ 9 Is Remote Access Service...

Страница 22: ...erations Console Note Do not remove the Service Pack CD until the PC is fully into its restart It will be accessed again after you click on Yes to restart After the restart to either install or reinst...

Страница 23: ...hanging in the Function Data display __ h Is reference code x6004501 where the x is there is a letter or number shown in the Function Data display No Yes Go to step 4 __ i Is the Attention light lit Y...

Страница 24: ...ould not get any of the Console only displays here __ 11 Click on Next to allow the system to detect the console communications port System should find the port and select it automatically If not manu...

Страница 25: ...You should see the IPL or Install the system menu Select Use Dedicated Service Tools DST Go to step 21 Use the Remote Control Panel on the PC If you don t have a Remote Control Panel on the PC go to t...

Страница 26: ...wing if not already done a Plug the system unit power cords into an electrical outlet b Plug in and power on all attached devices such as printers and displays c Look at the Function Data display on t...

Страница 27: ...e 2 Change next to the Resource name QESLINE l Press the Enter key m Change the Resource name from CMN01 to the Resource name that is written in step 3c n Press the Enter key The message Description f...

Страница 28: ...22 AS 400e 170 or 250 0367 Operations Console and 0381 Remote Control Panel Cable V4R5...

Страница 29: ...e Asia Corporation Licensing 2 31 Roppongi 3 chome Minato ku Tokyo 106 Japan The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent wi...

Страница 30: ...rrect the interference at his own expense Properly shielded and grounded cables and connectors IBM Part Number 75G5958 75G2865 97H7385 or its equivalent must be used in order to meet FCC emission limi...

Страница 31: ...product may cause radio interference in which case the user may be required to take adequate measures Trademarks The following terms are trademarks of the IBM Corporation in the United States or othe...

Страница 32: ...26 AS 400e 170 or 250 0367 Operations Console and 0381 Remote Control Panel Cable V4R5...

Страница 33: ...ation in this book is Very Satisfied Satisfied Neutral Dissatisfied Very Dissatisfied Accurate h h h h h Complete h h h h h Easy to find h h h h h Easy to understand h h h h h Well organized h h h h h...

Страница 34: ...ERK 3605 Highway 52 N ROCHESTER MN 55901 7829 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 35: ......

Страница 36: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SENG 0367 04...

Отзывы: