IBERITAL DE RECAMBIOS, S.A.
Page 20 of 22
manual electr.ce ingles 22-11-2004.doc
2.3.- ELECTRICAL CONNECTION
IMPORTANT: This equipment is to be permanently cord connected.
The machine is fitted with a heating and other electric elements of either 110V, 220V or 240V
depending on the version. A circuit breaker (17), with an adequately rated fuse, must be fitted
between the appliance and the mains. The maximum power consumption is indicated on the
data plate (20).
The yellow/green wire must be connected to an efficient grounding installation.
220V-240V SINGLE PHASE.
The machine can be connected in single phase, in this case the black wire should be joined
together with the brown wire and then connected to phase. The blue wire must be connected
to other phase. Green wire to ground.
Black Brown Blue( or Grey ) Yellow/Green
--///
Phase (R)
Phase (S)
220V-240V THREE PHASE WITHOUT NEUTRAL.
The machine can be connected in three phase 220V without neutral, to do this connect the
black wire to one of the three phases and the brown wire to another of the three phases and
then the blue wire to the remaining phase. Green wire to ground.
Black Brown Blue ( or Grey ) Yellow/Green
--///
Fase (R)
Fase (S)
Fase (T)