CLEANING
In order to obtain a correct cleanliness, exclusively wash them with soap and water, rewash and dry them with a soft
towel and deerskin. Avoid the usage of alcohol, solvents, solid or liquid detergents which contain corrosive or acidic
substances, abrasive sponges, swab with metallic strings because they could irreversibly compromise the surfaces.
THE USAGE OF THIS KIND OF DETERGNETS DURING THE CLEANING OF THE MIXER EXCLUDE IB RUBINETTE-
RIE FROM ANY WARRANTY OBLIGATION.
THROUBLE SHOOTING
ERROR
POSSIBLE PROBLEM
SOLUTION
The shower does not light up, no light
on the controls
No power to the control unit
Check that the LED on the DIVE
control unit is switched on. If it is
not check that the power supply is
properly connected
No power to the commands
If the LED on the DIVE control unit
is on, check that the data cable is
properly connected
Flow of intermittent, unstable and
noisy water
Presence of air inside the system
Keep the showerhead low to allow
the air to go out
The inlet valves do not open comple-
tely
Check and open all valves
Debris in the fi lters
Clean the fi lters if necessary
Unbalanced supply pressure
Check that the system is properly
installed and that there are no other
water requirements
Water temperature changes
Unbalanced supply pressure
Check that the system is properly
installed and that there are no other
water requirements
The boiler can not provide adequate
hot water
Mount a fl ow regulator at the hot
water inlet
Only hot water
Incorrect connection of hot and cold
water inlets
Check the hot and cold connections
and correct them if necessary
The DIVE control light fl ashes
Failure of the temperature sensor
Replace the DIVE control unit