Details of input and output signal
Signal type
Application
Signal
name
Contents Detail
Position data
designation
24bit data
-
24 bit integer with sign (unit: 0.01mm)
Set position data in hexadecimal number of 24 bits.
Example) In the case of +25.4mm, designate
0009EC
H
(decimal 2540).
(Note)
●
When the integer is negative, it is indicated by
complement of 2, therefore, the uppermost bit
becomes “1.”
Current limit
value
8bit data
-
Set current limit value when push to set push force
in hexadecimal number. (unit%)
Setting range is from 00
H
to FF
H
, and FF
H
=100%.
Example) When setting to 50%, set it as
FF
H
50%=255×50%=127(decimal)=7F
H
.
Speed
designation
24bit data
-
24 bit integer (unit 0.01mm/sec)
Set command speed in hexadecimal number.
Example) In the case of 200mm/sec, the data is
0004E20
H
(decimal 20000).
(Note)
●
When speed is not set, or setting is “0,” or the
setting is “0,” stop is kept. Alarm does not occur.
When changing the speed by changing the
setting to “0” during movement, it decelerates and
stops.
PLC in
put
Acceleration
and
deceleration
8bit data
-
Set acceleration and deceleration in hexadecimal
number.
(Unit: 0.01G)
Example) When setting to 0.2G, it is 14
H
. It is C8
H
(decimal 200) at maximum 2G.
(Note)
●
When acceleration and deceleration are not set,
note that setting of parameter No.9 “Acceleration
and deceleration initial value” is not applied.
Содержание CC-Link
Страница 1: ...IAI America Inc CC Link RCM GW CC Gateway Unit Operation ManualFirst Edition ...
Страница 4: ......
Страница 10: ...6 1 5 How to identify model RCM GW CC Basic model For CC Link Gateway unit ...
Страница 12: ...8 2 2 External dimension drawing Mounting dimension ...
Страница 78: ...74 ...
Страница 82: ...78 Position data measurement value Present position 1 2 3 4 4 5 6 7 ...
Страница 84: ...80 Speed acceleration and deceleration set value Actuator speed Speed n2 Speed n3 1 2 3 ...
Страница 88: ...84 Command position No Completion position No 1 2 3 4 5 6 ...
Страница 91: ...87 ...
Страница 93: ...89 ...
Страница 115: ...111 Command P No 1 to axes 0 1 Set CSTR to 1 Set CSTR to 0 Positioning completed One second timer 2 1 ...
Страница 125: ...121 No 3 Axis 1 pause No 3 Axis 1 pause lamp No 3 Axis 1 STP ...
Страница 130: ...126 ...
Страница 131: ......