4.3 Building of SIO communication network (SIO communication)
4.3.1 Wiring
(1) Basic
Item Contents
Number of connecting units
16 axes max. (Depends on the operation mode. Refer to “1.4 Features”)
Communication cable length
Total cable length 100m or shorter
Communication cable
Two-paired twisted pair shielded cable
Terminal resistor
Recommended cable: Taiyo Electric Wire & Cable
CAUTION
1. Provide a communication path via a bus connection, and be sure to connect a terminal resistor at the
end. A terminal resistor is incorporated into the gateway unit side, therefore, it is unnecessary to connect
it.
2. The communication cable should be supplied by customer. If the recommended communication cable
is not used, use an electric wire size AWG22.
(2) Link connection for PCON-SE, ACON-SE
Gateway unit
(Incorporating
terminal resistor)
e-CON connector (AMP made 4-1473562-4: Green)
e-CON connector (AMP made 3-1473562-4: Orange)
Junction (AMP made 3-1473574-4:)
Recommended brand HK-SB/20276 × L 2P ×
AWG22
SIO communication
main line
First axis
Second axis
n
th
axis
Controller link cable
CB-RCB-CTL002
Terminal resistor
R=220
Ω
1/4W
Содержание CC-Link
Страница 1: ...IAI America Inc CC Link RCM GW CC Gateway Unit Operation ManualFirst Edition ...
Страница 4: ......
Страница 10: ...6 1 5 How to identify model RCM GW CC Basic model For CC Link Gateway unit ...
Страница 12: ...8 2 2 External dimension drawing Mounting dimension ...
Страница 78: ...74 ...
Страница 82: ...78 Position data measurement value Present position 1 2 3 4 4 5 6 7 ...
Страница 84: ...80 Speed acceleration and deceleration set value Actuator speed Speed n2 Speed n3 1 2 3 ...
Страница 88: ...84 Command position No Completion position No 1 2 3 4 5 6 ...
Страница 91: ...87 ...
Страница 93: ...89 ...
Страница 115: ...111 Command P No 1 to axes 0 1 Set CSTR to 1 Set CSTR to 0 Positioning completed One second timer 2 1 ...
Страница 125: ...121 No 3 Axis 1 pause No 3 Axis 1 pause lamp No 3 Axis 1 STP ...
Страница 130: ...126 ...
Страница 131: ......