Z
8
MINIMUM FLOW ADJUSTMENT FOR OVEN
THERMOSTAT
In order to adjust the minimum, act as follows: switch
the burner on turning the knob to the maximum position.
Remove the knob and unscrew of some turns the by-
pass screw (fig. I).
Assemble the knob and let the oven warm up for 15
minutes; after that turn the knob to the maximum
position.
After having removed the knob once again, making
sure that the thermostat rod has not been moved,
screw slightly the above mentioned by-pass screw, to
obtain a flame of 3 or 4 mm of length.
For U-LPG, the adjusting screw must be tight screwed.
Make sure that the flame does not extinguish passing
quickly from the maximum flow to the minimum flow,
and closing and opening the oven door (the oven door
must be closed softly).
Fig. I