TAB. D
Natural Gas 1.00
Jet mm Ø
Burners Power MJ/h
Oven
NG Regulator
Gas Type kPa
U - LPG 2.75
Jet mm Ø
Burners Power MJ/h
Oven
LP Test point
adaptor
Gas Type kPa
1.35
8.64
7.50
0.73
7
GAS CONVERSION AND ADJUSTMENT
SPECIAL NOTE
When converting from Natural Gas to U-LPG ensure that the NG regulator is removed and replaced
with the Test Point Assembly. A gas regulator suitable for a supply pressure of 2,75kPa should be part
of the gas tank supply.
After installation or any servicing operation, always ensure that the appliance is gas sound and that
the components are now operating correctly. Items removed during servicing should be replaced in
the reverse order to their removal.
Fig. B
GAS CONVERSION AND ADJUSTMENT
If the appliance requires a different type of gas than
the kind available, the injectors must be changed
and the minimum adjusted.
Oven burner
To change the oven injector, it is necessary to act as
follows: open the oven door, remove the lower side
A
, unscrew screw
B
(fi.g A) and disassemble the oven
burner
C
(see fig.B). Change the injector (see fig. B)
and replace it with another one suitable for the new
gas type (see table D).
Re-assemble everything in the opposite direction,
paying attention to place the burner in the right way
on its rear slot.
C
Injector
A
B
B
A
Fig. A
Fan assisted gas oven
Fan assisted gas oven
When used with natural gas all burners have been preset at our factory and further adjustment should
not be necessary. Conversion kits to other gases are available from the place of purchase.
Do not attempt to fit the conversion kit yourself. Conversion to U-LPG gas should only be carried out
by an authorized technician.