background image

Chapter 3 - Hardware 

 0818D 

User’s 

Guide 

3-14 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

This page was intentionally left blank

Содержание 0818D

Страница 1: ...0818D User s Guide Doc No 1002830 Rev 3 User s Guide 0818D CompactPCI System ...

Страница 2: ...C is a registered trademark of International Business Machines Corporation Intel and Pentium are registered trademarks of Intel Corporation Award is a registered trademark of Award Software Inc Other product names mentioned herein are used for identification purposes only and may be trademarks and or registered trademarks of their respective companies Customer Service Worldwide Headquarters I Bus ...

Страница 3: ...0818D User s Guide 3 ...

Страница 4: ... Power Modules 2 5 2 2 4 Backplane 2 5 2 2 4 1 cPCI Backplane 2 6 2 2 4 2 Backplane CMC Connector 2 6 2 2 5 Hardware 2 7 2 2 5 1 CMC Board 2 7 2 2 6 Software 2 8 2 3 Environmental 2 8 2 3 1 Temperature 2 8 2 3 2 Humidity 2 8 2 3 3 Altitude 2 8 2 3 4 Vibration Shock 2 9 2 3 5 Safety Agency 2 9 Chapter 3 Hardware 3 1 SBC Module 3 2 3 1 1 Removal of the SBC Board Module 3 2 3 1 2 Installation of the ...

Страница 5: ...3 4 1 4 Alarm Cut Off LED ACO 3 7 3 4 1 5 CMC Health LED CMC 3 7 3 4 1 6 Reset Pushbutton RST 3 7 3 4 1 7 LED Test Pushbutton 3 7 3 4 1 8 ACO Off Pushbutton 3 8 3 4 1 9 Battery Pushbutton 3 8 3 4 2 Removal of the CMC Board 3 8 3 4 3 Insertion of a CMC Board 3 8 3 5 Backplane 3 9 3 6 Backplane Cooling Fans and Blowers 3 10 3 6 1 Removal of the Hot Swap Fan Tray 3 10 3 6 2 Installation of the Hot Sw...

Страница 6: ...a Power Supply Module 4 5 4 3 Input Circuit Breaker 4 5 Chapter 5 Software Software 5 1 Chapter 6 Platform Management Option 6 1 Overview 6 1 6 2 Description 6 1 6 3 CMC Board Mechanical and Environmental Specifications 6 3 6 3 1 Physical Size 6 3 6 3 2 User Access 6 3 6 3 3 Temperature Range 6 3 6 4 Sensors Supported 6 3 6 4 1 Temperature Sensors 6 3 6 4 2 Voltage Sensors 6 4 6 4 3 Fan Sensors 6 ...

Страница 7: ...are 6 9 6 6 2 IPMI Command Interface Software 6 12 6 6 2 1 Packet Format 6 13 6 6 2 2 Timeouts 6 13 6 6 2 3 Watchdog Timer 6 13 6 7 CMC Connector Pins 6 14 6 7 1 CMC P3 Connector Pinout Assignments 6 14 6 7 2 CMC P4 Connector Pinout Assignments 6 15 6 7 3 NEBS CMC Relay Output Connector Pinouts 6 16 6 7 4 RS 232 Pinouts 6 16 6 7 5 Battery Connector 6 17 6 7 6 Pin Assignments for DB9 Connector for ...

Страница 8: ...ments I O Slot A1 6 P2 Signal Descriptions A1 7 P3 P4 P5 Connectors Pin Assignments System Slot A1 7 P4 Connector Pin Assignments Computer Telephony Bus I O Slot A1 8 P4 Signal Descriptions Computer Telephony Bus I O Slot A1 9 Appendix 2 Glossary of Terms Appendix 3 Limited Warranty Appendix 4 FCC Information ...

Страница 9: ...Table of Contents 0818D User s Guide 9 This page was intentionally left blank ...

Страница 10: ......

Страница 11: ... the Intel based I Bus 2801 The reliability of the 0818D system is further enhanced when powered by two alternative independent power sources The utilization of these power sources is controlled by DC input power modules The input modules plug into the computer backplane from the rear of the chassis The two modules are identical and their physical location determines which one is the preferred pow...

Страница 12: ...Chapter 1 Introduction 0818D User s Guide 1 2 This page was intentionally left blank ...

Страница 13: ...ystem It is designed for NEBS compliance for rack mount CompactPCI systems The system accommodates one 2400 or one 2801 SBC in the system slot of each 8 slot cPCI segment within the custom monolithic backplane In a 2400 configuration the system accommodates up to 16 2802 SBC s in the node slots and up to two PICMG 2 16 compliant Ethernet fabric switch boards The power supplies and cooling devices ...

Страница 14: ...PMB Figure 2 1 0818D Block Diagram 2 2 Mechanical 2 2 1 Enclosure Designed for EIA RS 310 19 and 23 rack mounts Detachable rack mount brackets can be positioned for front flush mount or mid chassis rack mount The rack mount bracket design incorporates mounting keyways for temporary hanging of the chassis There are provisions for mounting four 4 front pluggable 3U X 6HP power supplies Enclosure fro...

Страница 15: ...d rear surfaces of the enclosure The top front panel mounts small alarm display board to show the alarm condition as well as a push button to disable the ACO and a pushbutton to check the integrity of the status LEDs The enclosure supports 80mm depth rear I O boards 2 2 1 1 Basic Chassis Configuration Eurocard 6U card cage per PICMG 2 0 Rev 3 0 CompactPCI specification Central 6U card cage with 18...

Страница 16: ...in Positronic interface DC input range is 42 to 68VDC Internal Power Factor Correction PFC meets IEC EN61000 3 requirements for harmonic distortion and flicker Individual maximum loads per power supply module are as follows 5VDC 25A 3 3VDC 20A 12VDC 5A 12VDC 0 5A Minimum load for 5VDC of each power supply module is 3A Combined maximum output current of 3 3VDC and 5VDC shall not be more than 30A pe...

Страница 17: ...se polarity will cause the input circuit breaker to trip Each DC module panel has three LED indicators Power Good The applied input is between 37 and 69 Vdc Active The module is supplying power to the system Thermal Fault The system has shut off due to over temperature Input Voltage Start Voltage 41V Min 43V Max Under voltage Cutoff 36 5V Min 37 5V Max Over voltage Cutoff 67V Min 70V Max Input Cur...

Страница 18: ... main input to the power supply section of the backplane is be through the DC Input module system The cPCI backplane provides a connector behind the Power Supply section for the purpose of connecting a stand alone CMC Chassis Management Controller board The cPCI backplane incorporates six sets of fan control signals originating on the CMC connector Each set of fan control signals includes FANTACH ...

Страница 19: ...sary to show status of the alarm The backplane CMC connector shall be located behind the power supply connectors on the cPCI backplane 2 2 5 Hardware The 0818D system consists of a single SBC connected to the CompactPCI backplane 2 2 5 1 CMC Board The CMC Chassis Management Controller board is optional It is a stand alone board supporting IPMI Intelligent Platform Management Interface version 1 0 ...

Страница 20: ... SBC that occupies the main system slot If this SBC is PICMG 2 9 compliant with a BMC the Chassis Management option applies Otherwise the System Management option applies 2 2 6 Software The 0818D supports the Sun Solaris 8 Microsoft Windows NT 4 0 Windows 2000 and Linux Red Hat Hard Hat with the appropriate I Bus supported SBC 2 3 Environmental 2 3 1 Temperature Operating temperature 0 C to 40 C S...

Страница 21: ...on Shock Operating vibration 0 25g 2 100 Hz 1 5g 100 500 Hz Storage transport vibration 2g 5 500 Hz Operating shock 10g 11 msec NEBS earthquake zone 4 Storage transport shock 30g 11 msec 2 3 5 Safety Agency UL 1950 cUL or CSA 950 TUV EN 60950 CE FCC Class A NEBS ...

Страница 22: ......

Страница 23: ...licate and can be easily bent Precise alignment and proper insertion ejection procedures are critical in order to avoid bending backplane pins Electrostatic Discharge ESD may damage memory chips programmed devices and other electrical components ESD can be prevented by wearing a wrist strap attached to a ground post on a static mat Handling of this product should ONLY be done by a properly trained...

Страница 24: ... the screws should be pushed inward to prevent obstructing the movement of the injector ejector handles 3 Completely retract the injector ejector handles by pressing them away from each other Note Some force may be required 4 Slide the SBC module out of the chassis 3 1 2 Installation of the SBC Board Module 1 With the Injector Ejector handles in their outward open position insert the SBC module on...

Страница 25: ...ems supported 3 2 1 Removal and Installation of I O Boards 1 Hot swap only Toggle the bottom injector ejector handle of the card down or activate the hot swap thumb switch Non Hot swap only Shut down the system and turn off the main system power 2 Hot swap only The card s blue LED should light indicating that the card is safe to remove 3 Loosen the screws on the add in board s faceplate if any 4 C...

Страница 26: ...card and accomplish the correct steps to allocate resources and load drivers 5 Secure the add in board module by tightening the two captive screws if they are present For hot swap instructions on other third party hot swap software consult the applicable instruction manual for the software 3 3 Rear I O Transition Modules The 0818D is configured to support rear I O transition modules 3 3 1 Removal ...

Страница 27: ...Module 1 With the Injector Ejector handles in their outward open position insert the rear I O module on its card guides until the handle latches begin to engage Make sure the two guide pins mate properly into the corresponding hole in the rear I O card guides 2 Engage the injector ejector handles by pressing them towards each other Note If a firm steady pressure on the handles does not readily sea...

Страница 28: ...ntroller Board The 0818D supports a Chassis Management Controller CMC Board in a connector slot located behind the power supply connectors on the rear of the cPCI backplane Refer to Chapter 6 for more information about this optional feature Figure 3 1 CMC Board Front Plate ...

Страница 29: ...n has been silenced by the ACO OFF pushbutton Should another alarm condition occur while the previous alarm condition is still present the LED will be extinguished and the audible alarm will again sound 3 4 1 5 CMC Health LED CMC Normally this LED is illuminated Green Should any software or hardware malfunction cause the CMC Board to become inoperative this LED will turn Red It will also turn Red ...

Страница 30: ...he CMC Board 3 4 2 Removal of the CMC Board 1 Shut down the system and turn off the main system power 2 Loosen the screws on the CMC board s faceplate if any 3 Completely retract the injector ejector handles of the rear I O board module by pressing them away from each other Note Some force may be required 4 Slide the CMC board module out of the chassis Note If you do not plan on immediately replac...

Страница 31: ...d module by tightening the two captive screws if they are present 3 5 Backplane The 0818D backplane is designed to be PICMG 2 16 compliant The backplane supports 16 node slots with 2 fabric slots The system can be configured in to a two independent 8 slot CPCI bus segments CAUTION In the 0818D system the SBC occupies slot 1 and or slot 9 Do not attempt to remove the backplane from the chassis The ...

Страница 32: ...hdrawn 3 6 1 Removal of the Hot Swap Fan Tray Note Removing the fan tray interrupts power to all fans Therefore if the fan tray is being hot swapped you should have another fan tray ready to install immediately after the first one is removed to prevent the unit from overheating 1 Loosen the captive Thumb Screw located on the right hand end of the fan access cover at the bottom front of the enclosu...

Страница 33: ...oling Blowers Three cooling blowers force hot air out the exhaust openings at the top rear of the chassis The blowers may be individually hot swapped as follows 1 Loosen the captive thumbscrew at the right hand end of the blower access cover at the top front of the chassis see Figure 3 4 Figure 3 4 Blower Access Cover Figure 3 5 Cooling Blowers one partially withdrawn 2 Remove the access cover and...

Страница 34: ...huttle with the guide tracks in the chassis and slide it into the chassis Press firmly to engage the power connectors at the rear of the chassis If the system is energized and the blower is correctly aligned it will immediately start running as contact is made with the rear power connectors 2 Replace the blower access cover being careful that the LED s and small pushbuttons properly align with and...

Страница 35: ...ghly dried before replacing it 3 7 1 Removing the Chassis Filter 1 Loosen the captive thumbscrew located on the right hand end of the fan access cover at the bottom front of the chassis 2 Remove the access cover 3 Remove the filter from the access cover and clean it If the filter is washed it should be thoroughly dried before replacing it 3 7 2 Replacing the Chassis Filter 1 Replace the filter in ...

Страница 36: ...Chapter 3 Hardware 0818D User s Guide 3 14 This page was intentionally left blank ...

Страница 37: ... supply and input circuit breaker and provides installation and removal instructions for each CAUTION 4 1 Dual Input Power Modules The reliability of the 0818D system is enhanced by being powered by two independent DC power sources The utilization of these two power sources is controlled by two input power modules each fed by a different and separate source of power No interconnection wiring betwe...

Страница 38: ...e preferred input The module plugged into slot B bottom slot becomes the secondary power input If the output from the primary module goes outside its specified limits transfer to the secondary module occurs within 100 microseconds so the system will continue to operate without interruption Figure 4 2 Rear View of Chassis Showing DC Input Power Modules Warning If both input power modules are fully ...

Страница 39: ...e s faceplate as much as possible Note The screws are captive to the faceplate and cannot be completely removed 3 Lift up the injector ejector handle fully to release the module from the backplane 4 Slide the module out of the chassis 4 1 3 Installation of an Input Power Module 1 Slide the replacement power module into the chassis and engage the injector ejector handle by pressing it to its full d...

Страница 40: ...ower supply modules Figure 4 3 2 Loosen the two captive screws on the power supply module s faceplate as much as possible Note The screws are captive to the faceplate and cannot be completely removed 3 Depress the injector ejector handle latch and pull the handle outward to release the power supply module from its backplane connectors Note This may require some force 4 Slide the power supply modul...

Страница 41: ...ecure the power supply module by tightening the two captive faceplate screws Figure 4 4 Power Supply Module Partially Withdrawn 4 3 Input Circuit Breaker The DC Input Power Module has a single pole 25 ampere circuit breaker in the negative input lead as well as a 30 ampere fuse in the positive input lead The ON OFF switch on the front panel is used to interrupt or restore DC power from the power s...

Страница 42: ...Chapter 4 Power Distribution 0818D User s Guide 4 6 This page was intentionally left blank ...

Страница 43: ...indows 2000 Windows NT 4 0 or Linux operating system or with the SUN Solaris 7 or 8 operating system For software configuration support on this platform refer to the software manufacturer s Installation and Configuration manual For other third party software refer to the appropriate User s Manual ...

Страница 44: ...Chapter 5 Software 0818D User s Guide 5 2 This page was intentionally left blank ...

Страница 45: ...rotocol Local I 2 C bus to connect temperature sensors and any other remote sensing devices The IPMB0 is driven by an I 2 C bus controller 6 2 Description The CMC Board is plugged into the back of an I Bus cPCI monolithic backplane and mounted vertically behind the power supply connectors Figure 6 1 shows the architecture of a CMC Board in conjunction with the SBC s in a cPCI system The CMC board ...

Страница 46: ...out 2 in RS 232 IPMB0 Figure 6 1 Block Diagram of a Chassis Management Controller Figure 6 2 shows the I2C ports assignment between the CMC controller chip e g VSC215 and the CompactPCI backplane CMC Controller Chip eg VSC215 CMC Backkplane Connector H1 H2 H3 H4 H1 H4 1x5 pin header pin1 SCL pin2 GND pin3 SDA pin4 5V IPMB PWR pin5 ALERT I2C1_x I2C2_x I2C3_x to backplane IPMB0 to backplane IPMB1 LM...

Страница 47: ...0_C to 55_C Storage 40_C to 85_C 6 4 Sensors Supported The CMC board is capable of reading temperatures DC voltages fan tachometers fan health and power supply health It can also output alarm conditions on the relay outputs and LEDs 6 4 1 Temperature Sensors There are connector s in the backplane to extend the Local I C bus I2C3_CLK and I2C3_SDA to the external temperature sensor modules LM75s The...

Страница 48: ...3 3V Battery Output By default voltage sensors will trigger major alarms when their threshold limits are exceeded The CMC also monitors the input voltage on the input modules Note that in a chassis that uses AC power the thresholds reflect the fact that the AC input modules will accept AC power between 90 and 260 volts No alarm is triggered at abnormal voltages like 180 Volt sensors 5 and 6 monito...

Страница 49: ...1 on any of the digital fan sensor causes a minor alarm 6 4 4 Power Supply Sensors Power supply sensors detect the health of individual power supplies If a power supply is good its sensor will read 0 A reading of 1 indicates that the power supply is not healthy By default this will cause a major alarm 6 4 5 IPMB Power The 5V DC IPMB Power on the bus is regulated separately from the rest of the CMC...

Страница 50: ... NO Common and 1 Kilo ohm Resistor Common 6 5 2 Battery Backup The CMC board provides a battery charger for charging an on board 6V sealed rechargeable battery The CMC Board generates IPMB_PWR when powered by battery backup The CMC Board will continue to operate when powered by battery backup The CMC Board provides a connector to an external 6V battery The recommended battery is POWERSONIC PS 605 ...

Страница 51: ...5 CMC Reset Switch There is an inset reset pushbutton on the CMC board to reset the CMC micro controller 6 5 6 Digital Input Output The CMC Board provides three TTL Level Inputs and three TTL Level Outputs accessible on a DB9 connector 6 5 7 ACO Alarm Cut Off The CMC board provides an external pushbutton input to allow the user to disable the audible alarm The ACO pushbutton operates as a toggle s...

Страница 52: ...ce is CRITICAL MAJOR MINOR ACO and CMC LEDs 6 5 10 Display Status Board The CMC board is able to control an external LED display status board to display the alarm status of the system The display status signals are provided via the backplane The following signals are on the CompactPCI connector for the CMC CRITICAL LED red MAJOR LED orange MINOR LED yellow ACO LED yellow ACO PUSHBUTTON SELF TEST P...

Страница 53: ...TERS on page 6 10 and are incorporated in the firmware All sensor information must be interpreted after reading SDR data from the CMC via IPMI commands The SDR data required for interpreting a sensor s output is available via the Get Sensor Reading Factors command The documentation for this command explaining how to perform the conversion can be found in the I Bus Platform Management Programmer s ...

Страница 54: ...the CMC controller on power up Table 6 1 Default SDR Parameters Sensor Nominal Normal Maximum Normal Minimum Upper Non Recovera ble Threshold Upper Critical Threshold Upper Non Critical Threshold Temp0 25 C 40 C 5 C 50 C 45 C 40 C Temp1 25 C 40 C 5 C 50 C 45 C 40 C Temp7 40 C 55 C 20 C 70 C 65 C 55 C Fan0 3000 RPM 3400 RPM 2800 RPM 4000 RPM 3700 RPM 3500 RPM Fan1 3000 RPM 3400 RPM 2800 RPM 4000 RP...

Страница 55: ...A 0 00 0 00 Volt4 N A 11 0V N A 0 00 0 00 Volt5 N A 90V 40V N A 0 00 0 00 Volt6 N A 90V 40V N A 0 00 0 00 Volt7 N A 4 75 N A 0 00 0 00 PWR0 N A N A N A N A N A PWR1 N A N A N A N A N A PWR2 N A N A N A N A N A PWR3 N A N A N A N A N A Volt5 and Volt6 monitor input power to the chassis If the chassis uses AC power the first value shown in the table is used If the chassis uses DC power the second va...

Страница 56: ... interface uses the standard Block Transfer format as described in the IPMI 1 0 rev 1 1 specification section 9 The host must set a unique sequence number The response will use the same sequence number The command buffer must be no bigger then 36 bytes None of Block Transfer status registers or bits are used only the packet format 6 6 2 2 Timeouts Inter Byte Timeout The timeout between successive ...

Страница 57: ...D GND GND GND GND 4 I2 C1_CLK I2 C1_SDA IPMB_PWR I2 C2_CLK I2 C2_SDA GND 5 IPMB_PWR IPMB_PWR ALERT_1 IPMB_PWR IPMB_PWR GND 6 I2C3_CLK I2C3_SDA SYS_PRST GND 7 IPMB_PWR IPMB_PWR 48AvS GND 8 PWR_ON_OFF 48BvS GND 9 12V 12V 12V GND 10 GND 11 12V 12V GND 12 PWR_GD1 PWR_GD2 PWR_GD3 PWR_GD4 TEST_SW GND 13 PWR_EN1 PWR_EN2 PWR_EN3 PWR_EN4 GND 14 12V 12V 12V 12V 12V GND 15 P3_CRT MJR_LED MNR_LED ACO_LED ACO_...

Страница 58: ...SDA IPMB_PWR I2 C2_CLK I2 C2_SDA GND 5 IPMB_PWR IPMB_PWR ALERT_1 IPMB_PWR IPMB_PWR GND 6 I2C3_CLK I2C3_SDA GND 7 IPMB_PWR IPMB_PWR 48AvS GND 8 PWR_ON_OFF SYS_PRST 48BvS GND 9 12V 12V 12V GND 10 GND 11 GND 12 GND 13 GND 14 GND 15 GND 16 GND 17 12V 12V GND 18 PWR_GD1 PWR_GD2 PWR_GD3 PWR_GD4 TEST_SW GND 19 PWR_EN1 PWR_EN2 PWR_EN3 PWR_EN4 GND 20 12V 12V 12V 12V 12V GND 21 CRT_LED MJR_LED MNR_LED ACO_L...

Страница 59: ...ay Output Connector Pinouts PIN SIGNAL NAME 1 K1 RESISTOR COMMON 2 K1 COMMON 3 K1 N C 4 K1 N O 5 K2 RESISTOR COMMON 6 K2 COMMON 7 K2 N C 8 K2 N O 9 K3 RESISTOR COMMON 10 K3 COMMON 11 K3 N C 12 K3 N O 13 14 15 6 7 4 RS 232 Pinouts PIN SIGNAL NAME 1 2 TX 3 RX 4 5 GND 6 7 CTS 8 RTS 9 ...

Страница 60: ...ex type 22 11 2022 The mating cable connector is Molex type 22 01 3027 housing with 08 58 0110 terminals PIN SIGNAL NAME 1 Battery 2 Battery 6 7 6 Pin Assignments for DB9 Connector for Digital Input Output PIN SIGNAL NAME 1 Input 2 Input 3 Output 4 Output 5 GND 6 Input 7 GND 8 Output 9 GND ...

Страница 61: ...Chapter 6 Platform Management Option 0818D User s Guide 6 17 This page was intentionally left blank ...

Страница 62: ......

Страница 63: ... 1 GND 17 GND VCC3 IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL_ GND V I O STOP_ LOCK_ GND 15 GND VCC3 FRAME_ IRDY_ GND TRDY_ GND Key 12 14 11 GND AD 18 AD 17 AD 16 GND C BE 2 _ GND 10 GND AD 21 GND VCC3 AD 20 AD 19 GND 9 GND C BE 3 GND AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ_ GND VCC3 CLK0 AX 31 GND 5 GND BRSVP1A5 BRSVP1B5 PCI_RST_...

Страница 64: ... GND 17 GND VCC3 IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL_ GND V I O STOP_ LOCK_ GND 15 GND VCC3 FRAME_ IRDY_ BD_SEL_ TRDY_ GND Key 12 14 11 GND AD 18 AD 17 AD 16 GND C BE 2 _ GND 10 GND AD 21 GND VCC3 AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ_ GND VCC3 CLK AX 31 GND 5 GND BRSVP1A5 BRSVP1B5 PCI_R...

Страница 65: ...grant 0 signals REQ0_ Bus request 0 Interrupt Request INTA_ INTB_ INTC_ INTD_ Signals PCI Bus transaction FRAME_ Cycle Frame control signals TRDY_ Target Ready IRDY_ Initiator Ready STOP_ Target Initiator transaction stop bit IDSEL Initialization Device Select LOCK_ Resource Lock bit DEVSEL_ Device Select PCI bus error PERR_ Data Parity Error reporting signals SERR_ System Error PCI bus speed sign...

Страница 66: ...K Test Clock Scan Signals TDI Test Input TDO Test Output TMS Test Mode Select TRST_ Test Reset IDE Interrupts INTP Primary Interrupt IRQ14 INTS Secondary Interrupt IRQ15 Hot Swap compatible ENUM_ System Enumeration signals BD_SEL_ Board Slot Control HEALTHY_ Board Healthy ...

Страница 67: ... AD 34 AD 33 GND AD 32 GND 13 GND AD 38 GND V I O AD 37 AD 36 GND 12 GND AD 42 AD 41 AD 40 GND AD 39 GND 11 GND AD 45 GND V I O AD 44 AD 43 GND 10 GND AD 49 AD 48 AD 47 GND AD 46 GND 9 GND AD 52 GND V I O AD 51 AD 50 GND 8 GND AD 56 AD 55 AD 54 GND AD 53 GND 7 GND AD 59 GND V I O AD 58 AD 57 GND 6 GND AD 63 AD 62 AD 61 GND AD 60 GND 5 GND C BE 5 GND V I O C BE 4 _ PAR64 GND 4 GND V I O BRSVP2B4 C ...

Страница 68: ... AD 35 AD 34 AD 33 GND AD 32 GND 13 GND AD 38 GND V I O AD 37 AD 36 GND 12 GND AD 42 AD 41 AD 40 GND AD 39 GND 11 GND AD 45 GND V I O AD 44 AD 43 GND 10 GND AD 49 AD 48 AD 47 GND AD 46 GND 9 GND AD 52 GND V I O AD 51 AD 50 GND 8 GND AD 56 AD 55 AD 54 GND AD 53 GND 7 GND AD 59 GND V I O AD 58 AD 57 GND 6 GND AD 63 AD 62 AD 61 GND AD 60 GND 5 GND C BE 5 GND V I O C BE 4 _ PAR64 GND 4 GND V I O BRSVP...

Страница 69: ... DEG_ Degrade signal Power Supply FAL_ Supply Fail Signal Power Supply GA 4 0 Geographic Addressing SYSEN_ System slot identification Grounded at the system slot 64EN_ 64 bit bus enable P3 P4 P5 Connectors Pin Assignments System Slot P3 P4 and P5 are used for the purpose of providing access to the rear I O There is no connection on the backplane to these connectors at the system slot The P3 P4 and...

Страница 70: ...NP NP NP NP NP NP 15 NP Vbat NP NP NP VBatRtn NP Key 12 14 11 NP CT_D29 CT_D30 CT_D31 V I O CT_FRAME_A_ GND 10 NP CT_D27 VCC3 CT_D28 VCC CT_FRAME_B_ GND 9 NP CT_D24 CT_D25 CT_D25 GND FR_COMP_ GND 8 NP CT_D21 CT_D22 CT_D23 VCC CT_C8_A GND 7 NP CT_D19 VCC CT_D20 GND CT_C8_B GND 6 NP CT_D16 CT_D17 CT_D18 GND CT_NETREF_1 GND 5 NP CT_D13 CT_D14 CT_D15 VCC3 CT_NETREF_2 GND 4 NP CT_D11 VCC CT_D12 VCC3 SC...

Страница 71: ...s signals Computer 8Mfpbs Telephony CT_C8A 8 192 MHz data clock CT_C8_B Redundant 8 192 MHz data clock CT_FRAME_A_8 kHz frame clock CT_FRAME_B_ Redundant 8kHz frame clock CT_NETREF_1 8kHz 1 544MHz or 2 048MHz telecom network timing reference CT_NETREF_2 Secondary 8kHz 1 544MHz or 2 048MHz telecom network timing reference CT_MC 2Mbps message channel FR_COMP_ 8kHz SCbus compatibility frame clock SCL...

Страница 72: ...s Vbat Telecom power source VbatRtn Telecom power source return SELVbat Short loop battery voltage within SELV limits SELVbatRtn Short loop battery return voltage within SELV limits Telecom Ringing Bus VRG Bussed ringing voltage VRGRtn Bussed ringing voltage return for VRG ...

Страница 73: ...w power D disk access LED The LED located on the front control panel that indicates when the hard disk drive is active DRAM Dynamic Random Access Memory A type of computer memory that needs to be refreshed by a memory controller or it loses its information drive bay Area in the chassis where drives are mounted E electrostatic discharge ESD A sudden uncontrolled movement of accumulated electrical c...

Страница 74: ...y contains one or more of the following power switch reset switch Power ON LED disk access LED keyboard connector status display etc H hard drive A non volatile data storage device Hard drives magnetically store computer data on spinning internal disks I IDE Integrated Drive Electronics A standard protocol for signaling and communicating with a hard drive CD ROM drive or other peripheral device I ...

Страница 75: ...r supply has stabilized The power good line switches from 0 to 5 volts within one tenth to one half second after the power supply reaches normal voltage levels Whenever output voltage is out of normal operating range for any reason the power good signal goes back to zero power ON diagnostic LED The LED located on the front control panel that indicates that power is applied to the computer power su...

Страница 76: ... stopped and any data in memory is lost S SCSI Small Computer System Interface A high speed general purpose interface to storage devices SDR Sensor Data Record A record of data about a sensor The full description of the contents of these records can be found in IPMI version 1 0 section 28 1 SEL System Event Log A non volatile storage area and associated interfaces for storing system platform event...

Страница 77: ...ctive parts at purchaser s cost and deliver the defective parts to the purchaser This Limited Warranty shall not apply if the product has been misused carelessly handled defaced modified or altered or if unauthorized repairs have been attempted by others The above warranty is the only warranty authorized by I Bus and is in lieu of any implied warranties including implied warranty of merchantabilit...

Страница 78: ...Appendix 3 Limited Warranty 0818D User s Guide A3 2 This page was intentionally left blank ...

Страница 79: ...ercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense Changes or mod...

Страница 80: ...Appendix 4 FCC Information 0818D User s Guide A4 2 This page was intentionally left blank ...

Отзывы: