MAINTENANCE OF DIESEL GENERATOR
Maintenance of diesel generator
For the generator works in order it is very important to perform the
maintenance at fixed period.
The diesel generator is consisted of diesel engine, alternator,
control panel, frame etc. Please read relative manual for the maintenance.
Before maintaining the generator, stop the engine. Please perform
the maintenance in a well ventilated area as the gases and the
exhaust can be harmful.
Change lube oil
To perform the changing of the oil it is recommend to run the
engine at least for 15 min. in order to warm the oil so will be much
more easy to drain it.
The oil of the engine must be change after the first 30 hours of
running and them every 50 hours for the next three time and them
every 100 hours.
Please do not through the oil to normal rubbish can, deposit the
used oil in the appropite oil bin.
Interval for changin the lube oil:
First time 30 hours
Next three times 50 hours
Later Every 100 hours
OPEN TYPE GENERATOR:
a) Place a vessel bellow the oil-drain plug
b) Open the oil dipstick
c) Remove the oil drain plug
d) Let the oil complete flow out of the engine
e) Remove prime oil filter
f) Clean the prime oil filter with a brush and diesel
REPLACE PRIME OIL FILTER EVERY 500 hours
g) Screw the oil drain plug
h) Place the prime oil filter in the engine and tight the screw,
be sure the o-ring is not damage
i) Fill the engine with new oil.
32