S825/1 

 

TROUBLESHOOTING 

 

 
 

 

 

 

 

Fault 

Cause 

Remedy 

Fluid will not flow 
through meter 

a)  Foreign matter blocking 

rotors 
 

b)  Line strainer blocked 

 

c)  Damaged rotors 

 

d)  Meter connections over 

tightened 
 

e)  Fluid is too viscous 

Dismantle meter and clean 
rotors 
 
Clean strainer 
 
Replace rotors 
 
Re-adjust connections 
 
 
See specifications for 
maximum viscosity 

Reduced flow 
through meter 

a)  Strainer is partially blocked 

 

b)  Fluid is too viscous 
 

Clean strainer 
 
See specifications for 
maximum viscosity 

Meter reading 
inaccurate 

a)  Fluid rate is too high or too 

low 
 

b)  Fluid is too viscous 

 

c)  Excess wear caused by 

incorrect  installation 

See specifications for 
minimum and maximum 
flow rates 
Bleed air from system 
 
Check meter body and 
rotors.  Replace as 
required.  Refer to 
installation instructions. 

Fluid flows but no 
reading on meter 

a)  Bevel gear is loose on 

shaft 
 

b)  Rotor drive gear is 

damaged 
 

c)  Transmission gears 

damaged 
 

d)  Register gears damaged 

Tighten grub screws 
 
 
Replace rotors 
 
 
Replace gears 
 
 
Replace register assembly 

Fluid leaks into 
register 

a)  Cover plate seal worn or 

damaged 

Replace seal (check seal 
compatibility with fluid) 

Содержание HO Series

Страница 1: ... HO 40 A PM HO 50 A PM HO 25 S MM HO 25 S ME HO 25 S PM Please read carefully before commencing installation Registered Office HYTEK GB LIMITED Delta House Green Street Elsenham Bishop s Stortford CM22 6DS UK Registered in England No 1915382 Tel 44 0 1279 815 600 Fax 44 0 1279 812 978 email info hytekgb com Web www hytekgb com HO 25 A MM HO 40 A ME HO 25 A PM ...

Страница 2: ...overnment or local authorities IMPORTANT WARNING NOTES 1 This meter is only be used to measure diesel or liquids classed as cat 3 in accordance with European Regulation No 1272 2008 It must not be used to measure petrol or any other liquid with a similar flash point 2 This product must not be used if it is damaged or leaking located in a fully enclosed environment or not provided with adequate ven...

Страница 3: ... Aluminium Viton 23 250 0 5 257 18 1 1 2 F BSPP N A Reed 32 5P L HO50APM 2 Pulse Meter Aluminium Viton 30 300 0 5 257 18 2 F BSPP N A Reed 16P L HO25SMM 1 Mechanical Meter Stainless Steel Viton 20 200 0 5 485 34 1 F BSPP 4 digit 6 digit N A HO25SME 1 Electronic Meter Stainless Steel Viton 20 200 0 5 485 34 1 F BSPP 5 digit 7 digit N A HO25SPM 1 Pulse Meter Stainless Steel Viton 20 200 0 5 485 34 1...

Страница 4: ...ormal operation mode with the batch total showing 5 Calibration The calibration mode is accessed by pressing the SETUP button The calibration factor and the units of measure are then displayed with the calibration factor which can be adjusted by pressing the SETUP button until the digit to be changed is flashes This digit can then be increased by pressing the ON CLEAN button and decreased by press...

Страница 5: ...e by pressing the ON CLEAN or TOTAL button Once the unit of measure has been set and no more buttons are pressed the meter will return to the normal operation mode after 3 seconds and retain the changes made HO25 40 50AMM HO25SMM 1 Resettable totalizer To reset the lower resettable totalizer press the reset button 2 Calibration The calibration of these meters is factory set and cannot be adjusted ...

Страница 6: ...s for maximum viscosity Meter reading inaccurate a Fluid rate is too high or too low b Fluid is too viscous c Excess wear caused by incorrect installation See specifications for minimum and maximum flow rates Bleed air from system Check meter body and rotors Replace as required Refer to installation instructions Fluid flows but no reading on meter a Bevel gear is loose on shaft b Rotor drive gear ...

Страница 7: ...ription Qty No Description Qty 1 Measuring Assy 1 7 Rotor Oval Gear 1 1 2 Upper Cover Gland 1 8 Rotor Oval Gear Shaft 1 3 O ring Viton 1 9 Rotor Oval Gear Shaft Short 1 4 Upper Cover 1 10 Rotor Oval Gear 2 1 5 O ring Viton 1 11 Bolt 4 6 Meter Body 1 ...

Страница 8: ...nity for industrial environments 2006 42 EC Machinery Directive 97 23 EC Pressure Equipment Directive 2014 68 EU Pressure Equipment Directive effective date 19th July 2016 2012 19 EU Waste Electrical Electronic Equipment Regulations 2011 65 EU Restriction of Hazardous Substances Directive RoHS2 Declaration Number EU129 On behalf of the above named company I declare under our sole responsibility th...

Отзывы: