8 – Pump specifications
P
u
mp specificat
ions
HyPrecision 60S
Dimensions and weights
The shipping weight is for the pump, the pallet, and the packaging. Exact weights are taken at shipment.
Operating weight is for an unpackaged pump with hydraulic fluid.
Width
1,016 mm (40 in.)
Shipping weight
1,370 kg (3,020 lb)
Length
1,930 mm (76 in.)
Operating weight
1,451 kg (3,200 lb)
Height
1,422 mm (56 in.)
44.7 kW, 60 hp
50 Hz
60 Hz
Voltage
400 V
460 V
Full-load current
89.0 A
71.1 A
Primary circuit breaker rating
100.0 A
100.0 A
CUTTING WATER IN
Minimum
Maximum
Flow
9.5 L/minute
(2.5 gallons/minute)
—
Pressure
2.76 bar or 275.79 kPa
(40 psi)
7.93 bar or 792.90 kPa
(115 psi)
CUTTING WATER OUT
Flow
—
4.9 L/minute
(1.3 gallons/minute)
Pressure
551.58 bar or 55,158 kPa
(8,000 psi)
4,136.85 bar or 413,685 kPa
(60,000 psi)
Continuous pressure
—
4,136.85 bar or 413,685 kPa
(60,000 psi)
Cutting water pressure
factory setpoint
—
4,136.85 bar or 413,685 kPa
(60,000 psi)
Piercing water pressure
factory setpoint
1,38.95 bar or 137,895 kPa
(20,000 psi)
—
COOLING IN and COOLING OUT
Flow
11.4 L/minute
(3 gallons/minute)
—
Pressure
2.76 bar or 275.79 kPa
(40 psi)
7.93 bar or 792.90 kPa
(115 psi)
Содержание HyPrecision 50S
Страница 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Страница 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Страница 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Страница 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...