HyPrecision 50S/60S/75S
Operator Manual
808690
183
8 – Pump specifications
P
u
mp specificat
ions
Hydraulic fittings
This table shows maximum values. The torque necessary to make a sufficient seal depends on the condition of
the pipe threads and can be much lower than the maximum.
Hypertherm recommends using thread sealant on all NPT hydraulic fittings.
Lubricate the O-rings with hydraulic fluid or O-ring lubricant before assembly.
NPT
Size
Standard maximum torque
Maximum torque value when
using thread sealant
(75% of standard maximum)
Maximum torque value when
using a male tapered pipe
thread with a female straight
or parallel pipe thread
(50% of standard maximum)
N∙m
lbf∙ft
N∙m
lbf∙ft
N∙m
lbf∙ft
1/4 inch
34
25
26
19
18
13
3/8 inch
47
35
35
26
24
18
1/2 inch
61
45
46
34
31
23
3/4 inch
75
55
56
41
38
28
1 inch
88
65
66
49
45
33
1-1/4 inch
108
80
81
60
54
40
1-1/2 inch
129
95
96
71
65
48
Содержание HyPrecision 50S
Страница 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Страница 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Страница 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Страница 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...