5 – Preventive maintenance
Preventive main
tenance
23.
Put the needle assembly in the valve body.
24.
Push on the seal backup screw until it stops.
25.
Remove the seal backup screw. Put high-pressure antiseize lubricant on the threads.
26.
Use a socket wrench to tighten the seal backup screw in the valve body.