5 – Preventive maintenance
Preventi
ve maintenance
Replace the hydraulic fluid, the hydraulic filter, the filler-breather cap, and the
suction strainers
CAUTION
Failure to correct the cause of a leak can cause damage to the water fittings.
Follow local regulations when disposing of used fluids and filters.
Install a new hydraulic filter and filler-breather cap when replacing the hydraulic fluid.
Service
Interval
After every 1,500 hours of operation
Replace the hydraulic fluid and the suction strainers
After every 3,000 hours of operation
1
2
3
5
4
1
Filler-breather cap
2
Sight gauge
3
Access cover
4
Drain valve plug and lever
5
Hydraulic filter
6
7
8