106
HyPrecision 50S/60S/75S
Operator Manual
808690
5 – Preventive maintenance
Preventi
ve maintenance
Remove the indicator pin assembly
Required parts, tools, and materials
Clean, lint-free towels
Isopropyl alcohol
5/32-inch hex wrench
1.
Use a hex wrench to remove the socket-head cap screws and the lock washers from the indicator pin cap.
2.
Pull the indicator pin cap out of the hydraulic end cap.
3.
If the O-ring backup and the O-ring are being replaced, remove them from the indicator pin cap.
4.
Remove the spring from the indicator pin.
5.
Remove the indicator pin from the indicator pin hole in the hydraulic end cap.
6.
Clean each part with a lint-free towel and isopropyl alcohol. Examine all parts for deterioration, corrosion, or
damage.
Service
Interval
Replace the indicator pin spring
After every 3,000 hours of operation
Replace the indicator pin
After every 6,000 hours of operation
Do not use soap, detergent, or solvents.
1
3
4
5
6
2
1
Cap screws and lock washers
2
Indicator pin cap
3
Indicator pin O-ring backup
4
Indicator pin O-ring
5
Indicator pin spring
6
Indicator pin
Содержание HyPrecision 50S
Страница 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Страница 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Страница 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Страница 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...