Page 51
13. Technical specifications
208 V
Unit type
FLH15
Steam output [lb/h]
26,9 -
26,9
- 36,6
Electrical connection
(1)
208 -
208
- 240V /1Ph /N /50-60Hz
208 -
208
- 240V /3Ph /50-60Hz
208 -
208
- 240V /1Ph /N /50-60Hz
Rated power [kW]
9,3 -
9,3
- 12,4
Nominal current [A]
25,9 -
25,9
- 29,9
Fuse [A]
1 x 16
3 x 16
1 x 25
3 x 25
3 x 35
Connection terminals max. [in²]
0,4
Number of steam cylinder
Control
Control voltage
(3)
Steam hose connection [in]
Water consumption
(7)
[usgal/h]
19,92
Water flow rate
(8)
[usgal/min]
0,74 / 5,81
Max. filling capacity [usgal]
3,7
Empty weight [lb]
55,1
Operation weight [lb]
87,1
Width
(9)
[in]
21,3
Height
(9)
[in]
27,4
Depth
(9)
[in]
Water connection
Drain water connection
(1)
Other voltages on request
(3)
Separate control voltage on request
(7)
Maximum water consumption at 100% demand plus blow down losses. Water consumption depends on the water quality and options installed.
(8)
Flow rate of the feed water during refilling or pumping out. Unit without options / maximum rate with options.
(9)
Outer dimensions of width and depth. Height including drain connection
(11)
Units with production date January 2022 and earlier: 540 mm
208 -
208
- 240V /3Ph /50-60Hz
0,2
12,6
fully demineralised water / cleaned condensate / partially softened
tap water of varying qualities
1 to 10 bar, for 3/4" external thread
Connection Ø 1 1/4"
1 x 1,0
3,96
7,8
1,3
0,34 / 5,42
39,7
51,4
18,1
(11)
SPA units (FLE05-FLE15) will be delivered with a steam hose connection of 1x1,6 inch.
Technical data FlexLine Heater
21,1
8,8 -
8,8
- 10,2
17,7 -
17,7
- 20,4
1
FlexLine mainboard with capacitive 3.5" touch colour display
208 - 240V 2,5A
FLH03
FLH06
5,5 -
5,5
- 7,3
10,8 -
10,8
- 14,3
1,8 -
1,8
- 2,4
3,7 -
3,7
- 4,9