Winterizing

When freezing weather and/or power losses are expected, contact your local spa dealer 
for freeze protection or winterizing recommendations for both the spa and the equipment 
system. Freeze related damage is not covered by the warranty.

Chemical Water Treatment

Your dealer is familiar with local water conditions and which chemicals are compatible with 
and designed specifically for your spa. This is the best person to advise you on proper 
water quality management.
The one thing you can do to insure years of trouble free equipment operation is to 
maintain proper water chemistry.
Two basic goals of the chemical water treatment are sanitizing and balancing the water.
Sanitizing simply means keeping the water free from living microorganisms including 
algae, bacteria, and viruses. The current most popular chemicals for sanitizing include 
chlorine, bromine, and ozone.
Balancing water means establishing a balance among pH, total alkalinity, and total 
hardness. Water that is unbalanced can corrode the spa and it’s support equipment or 
leave deposits of minerals. Properly balanced water is essential to allow the sanitizing 
chemical to work effectively. There are numerous chemical additives to help you in 
controlling pH, total hardness, and total alkalinity. 

NEVER

 use softened water when filling 

your spa. Softened water is extremely corrosive to metal parts of the spa equipment and 
may lead to unforeseen failure.
Sometimes, despite your most diligent efforts, your water may become too far out of 
balance to be managed chemically. At this point it is probably better to drain and clean the 
spa and start over with fresh water.
Equipment failure caused by improper water chemistry will not be covered under warranty.

OPERATIONAL CONSIDERATIONS CONT.

TROUBLESHOOTING

The following describes situations and possible solutions to common problems you may 
encounter as a spa owner. Note: your system may not include all components listed.

Nothing Operates

System Mis-Wire is ON 

- Refer to Page 7 or contact your local dealer.

Main Breaker is OFF

 -

 Set to On.

Sub-Panel Breaker Off

 -

 Set to On.

Equipment GFCI Off 

- Set to On.

Components not plugged in

 -

 Plug in components.

Power cord not plugged in

 

- Plug in power cord.

Overheat Protection Switch Tripped

 -

 Refer to Page 7 or contact your local dealer.

 No, Low or Surging Water Flow

Air Lock in Plumbing System 

-

 

“Bleed” the system.

Restricted Flow 

-

 

Insure that the water shut-off valves are open and that suction fittings are 
not blocked by debris.

Dirty Filter 

- Clean or replace filter.

Low Water Level 

- Increase water level to recommended level.

Содержание PLATINUM PS-9003

Страница 1: ...PS 9003 PS 9004 PLATINUM SERIES INSTALLATION OPERATION GUIDE ...

Страница 2: ......

Страница 3: ...10 Receptacles 10 Spa Light 10 Wet Connections 11 Pressure Switch 11 Thermostat Setting 11 System Timer Setting Filtration 12 Mode Selection 12 Topside Options 13 Topside 13 14 Heater Operation 14 OPTIONAL CORD ADAPTOR KIT 15 OPERATIONAL CONSIDERATIONS 15 Warm Weather Conditions 15 Filtration System 15 Winterizing 16 Chemical Water Treatment 16 TROUBLESHOOTING 16 18 SYSTEM DATA LABEL 19 WARRANTY I...

Страница 4: ... at least 5 feet 1 5m from all metal surfaces A spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected by a solid copper conductor attached to the ground bar on the terminal box that is provided for this purpose Refer to NEC and local codes in effect at the time of installation A ground or bonding bar is provided on the control box to permit connection ...

Страница 5: ...shock replace damaged cord immediately For Permanently Installed Units A terminal marked G or ground is provided in the wiring box located inside the equipment compartment To reduce the risk of electric shock connect the terminal or connector to the grounding terminal of your electrical service or supply panel with a continuous green insulated copper wire in accordance with National Electric Code ...

Страница 6: ...control box and heater assembly from carton and verify contents for completeness For a bottom installation of heater loosen the 2ea 3 8 nuts on the adjustable clamps then loosen the adjustable clamps just enough as to move freely Slide the heater between the feet placing the studs from the adjustable clamps into the slots provided on the feet and tighten the 2ea 3 8 nuts then tighten the adjustabl...

Страница 7: ... with the heater box pointing up Connect the power and control cords from the heater to the matching receptacles on the side of the control box Ground Bond the heater directly to the control box using the included 8 solid copper bonding wire Ground Bond the control box directly to the heater using the included 8 solid copper bonding wire Insert the sensor probe s under the sensor cover attached to...

Страница 8: ...electrical service is capable of handling the increased amperage Chart below refers to a 240 volt supply feed and reflects heater amperages only be sure to add all other equipment amperages for proper breaker sizing 4 0kw 16amps 4 5kw 18 7 amps 5 5kw 22 9 amps 8 0kw 33 3 amps 8 5kw 35 4 amps 9 0kw 37 5 amps 9 5kw 39 5 amps 10kw 41 6 amps 11kw 45 8 amps Care must be taken as to how the two heaters ...

Страница 9: ... Systems require a Neutral wire therefore the service required is as follows 120 volt systems require a three wire electrical service including ground consisting of Line 1 Black Neutral White and Ground Green system Line 2 Blue connected together with the Neutral White 240 volt systems require a four wire electrical service including ground consisting of Line 1 Black Line 2 Red Neutral White and G...

Страница 10: ...sure Locate the conversion terminal block and desired connector Use the Corresponding color wire for each receptacle to be converted Carefully remove connector from the Neutral side Step 2 Reinstall the connector onto the Line 2 side The conversion is complete and the circuit is now ready for a 240VAC component Note Repeat this procedure for each circuit System Configuration Cont We have made the ...

Страница 11: ...uired for all portable spas and hot tubs as specified in the National Electrical Code Article 680 The GFCI is designed to provide protection against potential electrical shock hazard should ground fault occur The installation of a properly sized Ground Circuit and Bonding Circuit is still required as detailed in the Installation Manual The GFCI in your particular installation may be installed at t...

Страница 12: ...1 wire to one of the heater connectors Securely connect the White 12AWG Line 2 wire to the second heater connectors Connect the Green 10AWG Ground wire to an existing ground point such as a metal enclosure Connections must be made without twisting or damaging heater posts USE 2 WRENCHES one to hold the post one to tighten the nut Equipment Connections Receptacles High Speed Low Speed Common Pump 1...

Страница 13: ...OFF and verify that the pressure switch circuit is once again OPEN 7 Turn power to the system OFF and reconnect pressure switch wires Reapply power to the system and operate the spa or hot tub as normal Thermostat Setting The Thermostat regulates the water temperature in your spa It is located on the front panel of the control box or on the optional deluxe Spaside Control Some spas may have both t...

Страница 14: ... not set time by rotating outer dial Do not rotate minute hand counterclockwise Set the operating times to provide filtration and or heating for the number of hours per day recommended by your spa manufacturer We recommend at least two daily operating periods of not less than 1 hour each and spaced no more than 12 hours apart Heavy usage of your spa may require longer periods to maintain water cla...

Страница 15: ...ture readout Depending on how your spa is optioned it will normally have 2 to 4 control buttons They usually control the Jet Pump Secondary Jet Pump Air Blower and Light Topside Optional Topside Options Used with PS 9003 and PS 9004 High Volume Air Buttons Hole size 1 1 4 Tecmark Command Center 2 3 4 button 10 cord 3 1 4 x 6 1 2 Tecmark Digital Command Center 2 3 4 button 10 cord 3 1 4 x 6 1 2 ...

Страница 16: ...ations 120 Volts The heater will operate on demand at 4000 1500 Watts depending on the wattage selected during low speed pump operation It will automatically shut off when the high speed pump or blower is activated You can expect a heat rise of 1 F to 2 F per hour 240 Volt The heater will operate on demand at 4000 5500 Watts depending on the wattage selected during high and low speed pump operatio...

Страница 17: ...en provided This energy conservation feature may cause an inconvenience during warmer times of the year During warm periods of the year the temperature within the equipment compartment can elevate to a point that the pump will automatically turn off for a short period of time 15 30 minutes to allow the pump to cool down before automatically restarting This cool down feature will not harm your spa ...

Страница 18: ...hemical additives to help you in controlling pH total hardness and total alkalinity NEVER use softened water when filling your spa Softened water is extremely corrosive to metal parts of the spa equipment and may lead to unforeseen failure Sometimes despite your most diligent efforts your water may become too far out of balance to be managed chemically At this point it is probably better to drain ...

Страница 19: ...rotection Switch Tripped Press button to reset Air Button Switch Hose Not Connected Connect hose No Light Operation Light Bulb Defective Replace bulb or contact your local dealer Reflector has Fallen Off Replace deflector or contact your local dealer Light Not Plugged In Plug in the Light Air Button Switch Hose Not Connected Connect hose Water Leaks Spa Overfilled Adjust water level Too Many Peopl...

Страница 20: ...tting High Ambient Temperature Remove spa cover GFCI Trips Occasionally Lighting or Electrical storm Power Surge Extremely Humid Conditions or Radio Frequency interference Reset GFCI NOTE GFCI must be properly grounded or bonded GFCI Trips Immediately Defective Component Contact a qualified service technician or the factory for assistance ...

Страница 21: ...een found to be defective This warranty excludes damage as a result of normal wear freezing low voltage chemical abuse accident negligence alteration improper installation use or care To obtain warranty service return defective products within the warranty period to Hydro Quip The Hydro Quip Limited Warranty is for service on the control box only Purchaser is responsible for removal or reinstallat...

Страница 22: ...20 NOTES ...

Страница 23: ......

Страница 24: ...06 09 Rev 1 2 ...

Отзывы: