16
Winterizing
When freezing weather and/or power losses are expected, contact your local spa dealer
for freeze protection or winterizing recommendations for both the spa and the equipment
system. Freeze related damage is not covered by the warranty.
Chemical Water Treatment
Your dealer is familiar with local water conditions and which chemicals are compatible with
and designed specifically for your spa. This is the best person to advise you on proper
water quality management.
The one thing you can do to insure years of trouble free equipment operation is to
maintain proper water chemistry.
Two basic goals of the chemical water treatment are sanitizing and balancing the water.
Sanitizing simply means keeping the water free from living microorganisms including
algae, bacteria, and viruses. The current most popular chemicals for sanitizing include
chlorine, bromine, and ozone.
Balancing water means establishing a balance among pH, total alkalinity, and total
hardness. Water that is unbalanced can corrode the spa and it’s support equipment or
leave deposits of minerals. Properly balanced water is essential to allow the sanitizing
chemical to work effectively. There are numerous chemical additives to help you in
controlling pH, total hardness, and total alkalinity.
NEVER
use softened water when filling
your spa. Softened water is extremely corrosive to metal parts of the spa equipment and
may lead to unforeseen failure.
Sometimes, despite your most diligent efforts, your water may become too far out of
balance to be managed chemically. At this point it is probably better to drain and clean the
spa and start over with fresh water.
Equipment failure caused by improper water chemistry will not be covered under warranty.
OPERATIONAL CONSIDERATIONS CONT.
TROUBLESHOOTING
The following describes situations and possible solutions to common problems you may
encounter as a spa owner. Note: your system may not include all components listed.
Nothing Operates
System Mis-Wire is ON
- Refer to Page 7 or contact your local dealer.
Main Breaker is OFF
-
Set to On.
Sub-Panel Breaker Off
-
Set to On.
Equipment GFCI Off
- Set to On.
Components not plugged in
-
Plug in components.
Power cord not plugged in
- Plug in power cord.
Overheat Protection Switch Tripped
-
Refer to Page 7 or contact your local dealer.
No, Low or Surging Water Flow
Air Lock in Plumbing System
-
“Bleed” the system.
Restricted Flow
-
Insure that the water shut-off valves are open and that suction fittings are
not blocked by debris.
Dirty Filter
- Clean or replace filter.
Low Water Level
- Increase water level to recommended level.