background image

2

FCC ID: 2AHQR-10850A  IC ID: 21247-10850A

FCC: This product has been tested and found to comply with FCC part 15 subpart C. Operation is 
subject to the following two conditions: (1) this device may not cause Harmful interference, and (2) 
this device must accept any interference received, including interference that may cause undesired 
operation of the device. However, there is no guarantee that interference will not occur in a particular 
installation. If this device does cause harmful interference to radio or television reception, which can 
be determined by turning the equipment off and on. The user is encouraged to try to correct the 
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and 

receiver.

• Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help
Warning: Changes or modifications not expressly approved by the party responsible for compliance 
could void the user’s authority to operate the equipment. 
Industry Canada
This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject 
to the following two conditions: 1) this device may not cause interference, and 2) this device must 
accept any interference, including interference that may cause undesired operation of the device 
under Industry Canada regulations.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio 
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit 
pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique 
subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Warning: FCC and IC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. 
The antenna(s) used for this equipment must be installed to provide a separation distance of at least 
8 inches (20 cm) from all persons.
Cet équipement est conforme à l’exposition aux radiations de FCC et d’Industrie Canada établies 
pour un environnement non contrôlé. L’antenne (s) utilisé pour cet équipement doit être installé pour 
fournir une distance d’au moins 20 cm à partir de toutes les personnes. 

WARNING

To avoid serious personal injury and damage to the equipment:

It is your responsibility to ensure that this control is safely installed according to all 

applicable codes and standards. Hydrolevel is not responsible for damages resulting 

from improper installation and/or maintenance.

•  Read manual and all product labels BEFORE using the equipment. Do not use unless 

you know the safe and proper operation of this equipment.

•  Keep this manual available for easy access by all users.
•  Replacement manuals are available at hydrolevel.com
•  Disconnect all power before opening the control.
•  Do not attempt to service the control. There are no user serviceable parts inside the 

control. Attempting to do so voids warranty.

This product is packaged with two AA lithium metal batteries and must be transported in 

accordance with all relevant and international regulations. Contact your freight company for more 

information. Hydrolevel is not responsible for damages resulting from improper transportation, 

installation and/or maintenance.

This symbol identifies practices, actions, or failure to act which could result in 

property damage or damage to the equipment.

Содержание OS-200

Страница 1: ...s completely before proceeding CAUTION To prevent serious burns boiler should be thoroughly cooled before installing or servicing control WARNING Frozen pipes water damage Central heating systems are prone to shut down as a result of power or fuel outages safety related fault conditions or equipment failure Installation of freeze protection monitoring or other precautions is recommended for unatte...

Страница 2: ...uillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement Warning FCC and IC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment The antenna s used for this equipment must be installed to provide a separation dista...

Страница 3: ...t appliances or other sources of electrical interference Easy access for wiring Approximately 5 feet 1 5 m off the finished floor Grasp the front cover by the fingertip grips on the top and bottom of the enclosure and pull the front cover off The enclosure is either mounted flush onto a wall or it can be placed onto a 2 x 4 non conductive electrical box The mounting holes in the enclosure accept 6...

Страница 4: ...dd a transformer supplied by others as shown below The receiver unit must be powered with 24 VAC Batteries in the Transmitter unit Remove the cover from the transmitter unit Insert the included batteries as marked on the battery holder 1 5V lithium batteries are required to provide the specified battery life and temperature range Alkaline batteries have short life spans and may fail during cold we...

Страница 5: ...evert to a power up condition a temperature of 75 F 24 C will be reported until the first transmission is received up to 10 minutes Communication Power Low Battery Link Wireless Outdoor Sensor 087 Receiver Communication Power Low Battery Link Wireless Outdoor Sensor 087 Receiver STEP 4 INSTALL TRANSMITTER The transmitter should be mounted on a northern exterior wall away from direct sunlight In or...

Страница 6: ...tdoor Reset AND Warm Weather Shutdown Attach the spade connectors to the right and center spade posts OR and C for full outdoor reset functionality including warm weather shutdown protection Wiring this way overrides the Thermal Targeting function of the HydroStat control Warm Weather Shutdown Only WWSD Connect the wire ends to the left and center spade connectors WWSD and C to add warm weather sh...

Страница 7: ...O O R D E S I G N T E M P E R A T U R E B O I L E R T E M P E R A T U R E STEP 6 SETTING THE HYDROSTAT CONTROL continued To set the desired warm weather shutdown temperature Press and hold the TEST SETTING BUTTON and simultaneously adjust the ECONOMY dial to the desired setting To turn the feature off which will allow space heating regardless of outdoor temperature press and hold the TEST SETTING ...

Страница 8: ...ns that for each 1 degree increase in outdoor temperature the boiler temperature will decrease 2 degrees Conversely for each 1 degree drop in outdoor temperature the boiler temperature will increase 2 degrees The control adds 10 degrees to the calculated reset temperature and provides a 20 degree differential for burner operation So if the control calculates a reset temperature of 150 F it will se...

Страница 9: ...hat the communication LED turns green The battery life of the transmitter batteries may have expired This is likely the issue if the batteries have been in extended service They can be replaced with 1 5V lithium batteries The link may have been interrupted Try re linking the devices as described on page 4 3 If the communication LED remains off for over 30 minutes please call Tech Support at 203 77...

Страница 10: ...30307 13 F 25 C 97007 4 F 20 C 72910 5 F 15 C 55303 14 F 10 C 42316 23 F 5 C 32651 32 F 0 C 25395 41 F 5 C 19903 50 F 10 C 15714 59 F 15 C 12493 68 F 20 C 10000 77 F 25 C 8056 86 F 30 C 6530 95 F 35 C 5325 104 F 40 C 4367 113 F 45 C 3601 122 F 50 C 2985 131 F 55 C 2487 140 F 60 C 10K Type 2 NTC Thermistor ...

Страница 11: ... 7 8 W x 7 8 D 120 x 74 x 23 mm Enclosure Transmitter White ABS plastic NEMA 4X Receiver White PVC plastic NEMA Type 1 Packaged Weight 0 92 lb 420g Sensor 10K Type 2 Approvals FCC and IC Operating range Transmitter 40 to 140 F 40 to 60 C Receiver Indoor use only 32 to 122 F 0 to 50 C RH 90 non condensing Receiver power 24 V ac 10 1 VA ...

Страница 12: ...products which is made within such period we will at our option repair or replace such products or refund the purchase price paid to us by you for such products In no event shall Hydrolevel Company be liable for any other loss or damage whether direct indirect incidental or consequential This warranty is your EXCLUSIVE remedy and shall be IN PLACE OF any other warranty or guarantee express or impl...