90
fi g.
6.15
6 - L
OAD
C
APACITIES
Load Capacities
A
MU #1
B
MU #2
C
Cantilever length
Remaining
capacity
Length
Capacity
Remaining
capacity
Cantilever
length
None
5' (1,5 m)
10' (3 m)
15' (4,6 m)
20' (6,1 m)
CW =
2500 lb
(1
134 kg)
CW =
1500 lb
(680 kg)
Remaining
capacity
3500 lb
(1588 kg)
CW =
500 lb
(227 kg)
Remaining
capacity
4000 lb
(1814 kg)
No CW
Capacities
as shown
on
fi g.
6.4,
p. 83
No CW
Capacities
as shown
on
fi g.
6.4,
p. 83
8000 lb
(3629 kg)
12' (3,7 m)
1
1,500 lb
(5216 kg)
8900 lb
(4037 kg)
Any
cantilever
as shown
on
fi g.
6.4,
p. 83
22' (6,7 m)
10,500 lb
(4763 kg)
32' (9,8 m)
9000 lb
(4082 kg)
42' (12,8 m)
7500 lb
(3402 kg)
52' (15,8 m)
6500 lb
(2948 kg)
62' (18,9 m)
5000 lb
(2268 kg)
A
MU # 1
MU # 2
24' (7,3 m)
motorized unit
24' (7,3 m)
motorized unit
B
C
Angled and Corner Installations – Outside Corner
Angled and Corner Installations – Outside Corner
with 24' (7,3 m) motorized units
with 24' (7,3 m) motorized units
CW
Counterweight must be installed
between the mast and the edge of
the unit
Outside corner