background image

P a g e

 | 

12 

 

4.

 

Recheck gate setting as they may have adjusted during 
repositioning of adaptor fixing plate.  

 

Maintenance 

As FlowBright is constructed and installed in a simply and easy to understand 
way, maintaining it is also straightforward. We recommend that you remove 
the light from your inlet once every six months. Have a look over the product 
to make sure that no faults have occurred, remove any potential debris from 
the housing, cleaning any residue that may have formed. Once you’ve done 
this, simply reattached the product.  

Pool Chemistry  

To keep your FlowBright functioning properly, correct pool chemistry and 
water maintenance is essential. Water temperature should be not fall below 
10° degrees centigrade or go beyond 40° degrees centigrade. pH should be in 
the range of 7.2 – 7.6, and should never fall below 7.0, as this may cause 
issues with the materials used to construct the product. Alkalinity should be 
between 80-120, while calcium hardness should be 200-400 at a minimum. 
Chlorine needs to be no more than 2ppm. If you cannot guarantee these 
conditions, please contact your pool specialist. If you do install FlowBright in 
an environment that does not meet these requirements, your warranty may be 
void. 

 

 

 

Содержание FlowBright

Страница 1: ...FlowBright Instruction Manual ...

Страница 2: ...sformers niches or deck boxes With its straightforward design and precision engineered components FlowBright really does make your life easier However before you can enjoy FlowBright just give this instruction manual a read through Make sure you understand how the system works and how it should be installed We really want you to enjoy this product to its fullest in a safe and optimised manner If y...

Страница 3: ...ow Determination 9 Insufficient Flow 9 Excess Flow 10 Flow Chart 11 Adaptor Adjustment 11 Exhaust Adjustment 11 Maintenance 12 Pool Chemistry 12 Frequently Asked Questions 13 What happens when I backwash my pool 13 Will the light operate when I m vacuuming my pool 13 Can I use FlowBright in a salt pool 13 Patent Information 14 Product Specifications 14 Product Dimensions 14 Troubleshooting 15 Cont...

Страница 4: ...h the directional exhaust at the bottom of the system helping to improve circulation FlowBright has been designed to have very little impact on the back pressure in your filtration system This is made possible by using a sophisticated gate arrangement to divert excess water away from the turbine assembly If use of this gate arrangement is required excess water flow will exit from the back of the l...

Страница 5: ...emoved dried and stored during the winter period if the pool is out of use FlowBright is designed to screw into a standard 1 5 inch BSP female inlet fitting Other adaptors will be available shortly This version of FlowBright is recommended for residential applications and is not necessarily suitable for commercial situations Some small commercial pools may be appropriate However this decision shou...

Страница 6: ...should not be disassembled by unskilled persons Strong magnetic fields can be harmful to people with sensitive electronic medical devices such as pace makers When the light is fully assembled all the magnets are fully screened eliminating any potential hazard Warning When installing FlowBright do not let the distance between the back of the fascia and the wall of the pool become larger than 8mm Fl...

Страница 7: ... a g e 7 Technical Diagram Front View Rear view LED Array Fascia Directional Exhaust Long Adaptor Adaptor Fixing Plate Turbine 4 Gate Settings Housing Gate Setting Screw Adaptor Fixing Plate Screws Gates ...

Страница 8: ...let You need to be able to access the 1 5 inch female threads on your designated installation return inlet 2 Referring to the Flow Determination section below configure your FlowBright and or filter return system to the optimal setting 3 Before screwing FlowBright into your return inlet check which adaptor you require Short Adaptor Attached as standard If an adaptor change is necessary refer to th...

Страница 9: ...t function information about how to do this is below If you have flow above 7 0m3 h then you have an excess of flow and you should use the gate arrangements on your FlowBright Again the information about how to do this is below A low flow battery assisted FlowBright will be available soon designed specifically for very low flow rates usable when no flow is available Suitable for variable speed pum...

Страница 10: ... flows above 7 0m3 h If this is the case you will need to divert some of this excess flow away from the turbine If you do not do this the turbine will be rotating too fast and the pressure in your system will increase resulting in excess noise and wear Diverting the flow away from the turbine is very straightforward Use the flow Chart below to determine your required gate setting To adjust the gat...

Страница 11: ...ptor fixing plate by removing both the gate setting screw and the adaptor fixing plate screws 2 Remove the current adaptor 3 Replace with selected adaptor 4 Reattach the adaptor fixing plate Exhaust Adjustment When your FlowBright is installed into your pool you might discover that the directional exhaust is not located at the bottom of the housing If this is the case you should adjust your FlowBr...

Страница 12: ...y reattached the product Pool Chemistry To keep your FlowBright functioning properly correct pool chemistry and water maintenance is essential Water temperature should be not fall below 10 degrees centigrade or go beyond 40 degrees centigrade pH should be in the range of 7 2 7 6 and should never fall below 7 0 as this may cause issues with the materials used to construct the product Alkalinity sho...

Страница 13: ... at the filter the flow will momentarily stop causing the light to turn off Can I use FlowBright in a salt pool FlowBright is constructed out of the highest quality plastics and 316L stainless steel components These materials generally have a high resistance to corrosion under normal chlorinated pool water conditions With the addition of a salt chlorine generator the aggressiveness of the water to...

Страница 14: ...247807 USA US 8 618 687 Canada CA 2716172 Product Specifications Minimum Flow Rate 6 00 m3 h Max Flow Rate to Turbine 7 00 m3 h Max Flow Rate to Assembly 10 00 m3 h Min Temperature 10 C Max Temperature 40 C Remote Control Range 1 20m Lumens 1000 1500 Max Water Depth 1m Product Dimensions ...

Страница 15: ... Determination Light operates but poor light output Remote has poor response intermittent operations Low remote signal strength Remote control may be out of range Low battery Metal objects in the area are causing signal interference Back pressure raised in system Filter blockage Backwash or clean filter Flow through turbine too high Check by pass gate setting as you may need to change to a more op...

Страница 16: ...P a g e 16 Contact Information Hydro Flux Aqua Products Limited Unit 18 Wilton Industrial Court 851 Bradford Road Batley West Yorkshire WF17 8NN England 01924 472 665 Support hydro flux com ...