7.6
The histogram records the last 30 minutes of the machine run time. This gives a graphical representation of blade
deviation over time. To reset the data buffer power down the machine.
To set the clock:
1. Press PARAMETERS key
2. Type password (8797)
3. Press Enter key
4. Enter new time
5. Press Enter key
6. To Exit press RETURN (F1) function key
RELATIONSHIP BETWEEN BLADE DEFLECTION DISPLAY AND ACTUAL CUT DEVIATION
The digital display indicates the blade lateral deflection at the point where it passes the blade deflection sensor, which is
1” past the idler side guide arm. The maximum deviation of the cut surface will actually occur at or near the center of the
cut, and will be several times larger than that measured at the sensor. The display range of 0 +/-100 is proportional to the
amount of blade deviation. This depends on the type of material, shape of the work-piece and amount of blade tension.
The actual amount is difficult to predict, experience with different work-pieces will provide the best guide.
MANUAL MODE SCREEN
Cut out maximum limit
Cut in maximum limit
Current deflection
Cut out warning limit
Cut in warning limit
Fig.7