3.10
MITSUBISHI PLC 500 PARAMETER SCREEN (V18APC SHOWN)
NOTE:
For M16/20A and older V18APC (Before but not including serial # K0399163), the parameter screen is slightly different.
There will be only one Angle Calibration enable line (Reads: ANG CLB “ENTER” OFF), and only one Total Measured
Angle line (Reads: TTL MEAS ANG: 90.07).
MITSUBISHI PLC 500 PARAMETERS
To navigate through the parameters use the orange arrow keys to move the cursor. To change a parameter, move the
screen cursor to the desired parameter using the green arrow keys on the interface keypad. With the cursor on the value
to be changed, type in the new value with the numeric keys.
NOTE:
There are 4 parameters which can only be changed after the PLC does a ‘self calibration’. These parameters are:
ACT
LTH
(Actual
Length)
ACT HD MVT (Actual Head Movement)
TTL L MEAS ANG (Total Left Measured Angle)
TTL R MEAS ANG (Total Right Measured Angle)
(TTL MEAS ANG on M16/20 or older V18A)
Directly above each of these parameters will be the calibration procedure enable line. (ie. LTH CLB “ENTER” OFF). With
the cursor on the word ‘OFF’, the calibration procedure can be started by pressing the ENTER key.
NOTE:
If any calibration procedure is activated and not allowed to be completed, or a value for that parameter is not en-
tered during or after starting or completion of the procedure, the value for that parameter will reset to 00.000 and the PLC
will not be able to count/display the particular function for which the parameter is intended.
If any of the following problems occur, performing the calibration procedure may help:
NOTE:
Checks of mechanical & electrical components involved in the particular counting circuit should be made before
attempting calibrations.)
1. No length display with shuttle moving in manual/erratic length control/erratic shuttle movement - Perform Length
Calibration (LTH CLB)
2. No feed rate display (display reads FR 0.0 all the time) - Perform Head Height Calibration (HD CLB)
3. No angle display/improper angles in AUTO - Perform Angle Calibration (ANG CLB)
LENGTH CALIBRATION
If the machine has an out of stock switch put something in the shuttle vise to keep the out of stock from being activated.
With no material in the machine, proceed as follows:
1. With the cursor on the line that reads - LTH CLB “ENTER” OFF, press the ENTER key. The line should then read -
LTH CLB “ENTER” ON, and the cycle start button should be flashing.
Содержание M16A
Страница 2: ...2 ...
Страница 3: ...2 ...
Страница 38: ...2 20 ...
Страница 55: ...4 1 ELECTRICAL SCHEMATICS SEE PDF ON ATTACHED CD SECTION 4 ELECTRICAL ...
Страница 56: ...4 2 ...
Страница 60: ...6 1 MECHANICAL ASSEMBLY DRAWINGS PARTS LIST SEE PDF ON ATTACHED CD SECTION 6 MECHANICAL ASSEMBLIES ...
Страница 61: ...6 2 ...
Страница 68: ...7 7 AUTOMATIC MODE SCREEN Fig 8 ...
Страница 72: ...8 2 M16A LAYOUT ...
Страница 74: ...8 4 M20A LAYOUT ...
Страница 76: ...9 2 ...