USB interface
SensorMonitoring Unit - SMU
en(us)
Page 74 / 100
BeWa SMU1200 3854281 V2.0x en(us) 2013-08-20
2013-08-20
To save your measurements on the USB stick, proceed as follows:
1.
Open the protective cap to the
USB interface by unscrewing in
counterclockwise direction.
Insert the USB memory stick into
the socket. Note that the stick only
fits one way around.
It must be easy to insert the USB
stick into the socket.
2.
After inserting the USB memory
stick, the SMU will detect it and
immediately start copying the
measurement data.
DWNLOD
LOGS
3.
In the left-hand display, you can
see the number of measurement
records to be copied (e.g. 339)
The top right display shows the
number of records to be viewed
(e.g. 4). Only a 1 appears if you
are in the RING setting.
339
4
4a.
Memory setting FILL:
If the SMU detects existing
records on the USB memory stick,
the following message will appear
on the display.
Example: The SMU has found the
record number 4 on the USB
memory stick.
This function is especially suited to
the synchronization of the copied
data with the SMU's internal
memory. The existing records will
be displayed.
EXISTS
4
4b.
Memory setting RING:
If the SMU recognized the file with
the same data and number from
the same measured point on the
USB memory stick, the file ending
is incremented by 1.
(Example: file 09_02_06.001
287
1