Configuring the SMU
SensorMonitoring Unit - SMU
en(us)
Page 55 / 100
BeWa SMU1200 3854281 V2.0x en(us) 2013-08-20
2013-08-20
REC.MOD – Set data recording
Using the function REC.MOD, you can change the type of data recording.
You can select between two variants.
RING: Data is saved continuously. If the memory is full, then the oldest data
will be deleted in order to make it possible to continue to record. This
setting is recommended for stationary operation at a measurement
point. Then it will also be true that only one measurement point can
be selected in the Measuring Menu.
FILL: The data is stored until the memory available has been used up.
After this, no further data are recorded. The time period is dependent
on the REC.TIM setting in the measurement menu. This type of
storage is intended for when the SMU is used at different
measurement points. The DEL.MEM function is available for deletion
of the memory.
Use the following buttons to
set the memory type:
Change the
settings
o.k.
To confirm the
change
Esc
Cancel and
back
RING
The factory setting of the memory type is:
RING
Save the data to the USB memory stick before changing and deleting the
memory.
If the memory is not deleted after changing the
REC.MOD, then the SMU will display a NO.LOG.
NoLOG
If REC.MOD is already changed, then you will no longer be able to save the
data. To save the data elsewhere, restore the original setting.