Connecting the SMU
SensorMonitoring Unit - SMU
en(us)
Page 27 / 100
BeWa SMU1200 3854281 V2.0x en(us) 2013-08-20
2013-08-20
Sensor interface A - CS1000 IN / MCS1000 IN
Connect the sensor CS1000 / MCS1000 with this connection.
Sensor Interface B - AS1000 IN
Connect the sensor AS1000 with this connection.
Interface C - CS1000 OUT / MCS1000 OUT
Here the output signals of a connected CS1000 or MCS1000 can be tapped
into for further utilization.
The bus signals such as RS485 and HSI are not transferred by
the sensor.
The SMU has its own HSI interface (G).
Our accessories list includes cables of different lengths with one connection
plug and an open cable end.
The assignment of the connection cable is as follows:
Pin
Color code
CS1000
MCS1000
2
brown
Analog
Switching output 2
4
yellow
GND Analog signal /
switching output
GND switching output
8
Red
Switching output
(passive, n.c.)
Switching output 1
Please see the sensor documentation for more detailed information.