OffLine Filter OLF 15-30-45-60
Technical Description
HYDAC Filtertechnik GmbH
en
Page 40
BEWA OLF15-60 10bar 3255361-01a en.doc
2005-08-26
5
Range of application
The OffLine Filter OLF is a stationary filter unit, for use in an off-line kidney loop. It is
available with or without a pump/motor group. Use of aggressive or explosive materials in the
pump-motor group is prohibited. In case of questions, consult the manufacturer.
5.1 Models
The Offline-Filter OLF is offered in 4 standard models. Depending upon the viscosity of the
fluid, the following 3 different motor-pump groups can be supplied.
Pump types
Viscosity range
Vane pump
15 - 250 mm²/s
Gear pump
15
-
1000 mm²/s
Centrifugal pump
1
-
20 mm²/s
Without Pump
k.A.
5.2 Suitable
fluids
We recommend using the FluidAqua Mobil only with lubricating and mineral
oils or mineral oil based fluids or biodegradable liquids – based on synthetic
ester. Please contact us before using other fluids.
5.3
Element differential pressure
Differential pressure at 15l/min.
Differential pressure [bar]
Viscosity range [mm²/s]