Performing maintenance / inspection
FAM 15/30/50/70 ATEX
en(us)
Page 74 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
13. Fill the filter housing slowly.
Slightly undo the air bleed screw (x). The air
in the filter housing can escape via the slot
on the air bleed screw.
Bleed the filter housing through the air bleed
screw (x) until operating fluid comes out.
Tighten the air bleed screw.
14. The filter element change is now complete.
Checking the fault indicator lamp
After the FAM is switched on, all fault indicator lamps light up for 2 seconds.
Check to see whether all fault indicator lamps light up. Replace any defective
lamps immediately.