Performing maintenance / inspection
FAM 15/30/50/70 ATEX
en(us)
Page 73 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
10. Place the locking cap onto the filter element
(1).
Turn the locking cap 90° in the clockwise
direction to lock it in place.
No locking cap = no filtration.
11. Put the intermediate piece (b) on the lower
section (c).
Mount the lower housing tensioning clamp
(1), and tighten it with a torque of 20 Nm.
Secure using the lock nut.
Put the cover (a) on the intermediate piece
(b).
Mount the upper housing tensioning clamp
(2) and tighten it with a torque of 20 Nm.
Secure using the lock nut.
We recommend applying lubricant
containing a slip additive to the threads of
the housing tensioning clamp each time
filters are changed so that it remains easy to
remove.
Lubricant containing a slip additive – HYDAC
part no.: 3066287
12. Open all shut-off valves on the FAM (inlet
and outlet).
Switch on the FAM at the main switch.