Operating Elements on the unit
FAM 15/30/50/70 ATEX
en(us)
Page 44 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
Operating Elements on the unit
To operate the FAM, the following control and indicator elements are located
on the control panel:
Function
Quantity
Numbering
Function keys
3
S1 - S3
Operating status lamps
4
H1 - H4
Malfunction message lamps
11
H5 - H14
H4
H5
H6
H7
H8
H15
H9
H10 H11
H12
H13
H14
S1/H1 S2/H2 S3/H3
Function keys:
Inscription
Function
S1
Start delay
Start FAM, starting and changeover to
purification mode.
S2
Stop overrun
Stop FAM run-down and evacuation of the
vacuum column.
S3
Malfunction
Acknowledging all corrected malfunctions /
Switching from automatic to manual operation
Operating status lamps:
Inscription
Operating state
H1
Start delay
Startup phase
H2
Stop overrun
After-run phase
H3
Malfunction
Malfunction
H4
Fluid Aqua
operates
Purification operation