HYDAC FILTER SYSTEMS GMBH
Performing maintenance | 8
BeWa FCU1210 3545830b en-us lq
63 / 92
8.2 Clean the suction strainer.
1x Wrench
= 19 mm
Compressed air
The suction screen is fitted under the measurement point
union at the INLET connection and protects the pump from
contamination by coarse particles.
Clean the suction screen regularly. If the FCU is blocked or
there is no flow through the FCU, clean the suction screen
without delay.
NOTICE
Operation without a suction strainer
The FCU pump will be damaged / destroyed.
u
Never use the FCU without a suction strainer.
u
Clean the suction screen regularly.
To check/clean the suction strainer, proceed as follows:
ü
Remove all of the hydraulic and electrical connections to
the FCU.
1.
Loosen the INLET connector with a wrench (
= 19 mm) by turning it counterclockwise.