8 | Performing maintenance
HYDAC FILTER SYSTEMS GMBH
68 / 92
BeWa FCU1210 3545830b en-us lq
D Screw connection
NOTICE
Operation without a strainer
The flow control valve in the high-pressure adapter will be
damaged / destroyed
u
Never use the high-pressure adapter without a strainer
u
The suction strainer in the high-pressure adapter must be
cleaned regularly
1.
Remove the measurement coupling (A) from the
threaded joint (D) with a wrench (
= 22 mm) by turn-
ing it counterclockwise.
Then unscrew the strainer (B) counterclockwise with a
screwdriver or the special tool (see chapter Finding ac-
cessories).
2.
Clean strainer (B) and then blow it out with compressed
air.
3.
To fit the strainer (B), screw it in, clockwise, to union (D)
using a screwdriver or the special tool.
4.
Then check the sealing ring on the coupling (A) for dam-
age. Replace it/them if necessary.
5.
Screw in the coupling (A) in clockwise direction and
tighten it to 25 Nm.
ð
The cleaning / replacement of the strainer is complete.
The high-pressure adapter is ready for operation.