Input configuration
The values of the numerical and Boolean input values used in the CM Program
are stored in the input configuration file.
5.2.5.7 Set bus address
Here you can assign the CMU 1000 an "HSI Bus address". This is required when
several CMU 1000 (or other HYDAC CM devices) are connected to one HSI Bus
and these devices are all set up to be be addressed by a central PC. A total of a
maximum of 26 HYDAC CM devices can be linked to one HSI Bus, i.e. you can
assign the addresses "a" to "z" (see Chap. 5.2.2. CMU 1000 at the HSI Bus).
If the CMU 1000 is operated as a single device, then the bus address setting is not
required; it is not relevant for operational purposes.
The standard setting is "Address a".