8.4.3 Invalid Digital Output
The quantity of digital outputs is device-dependent. This error is set when an output
terminal is selected that a device doesn't have.
►
Check the selection and correct it.
8.4.4 Duplicate Digital Ouput
The output terminal of the digital output may not be present more than once in a CM
program.
►
Check the adjusted output terminal and correct it.
8.4.5 Invalid Analog Output
The quantity of analog outputs is device-dependent. This error is set when an output
is selected that a device doesn't have.
►
Check the selection and correct it.
8.4.6 Duplicate Analog Output
The set output of the analog output may not be present more than once in a CM
program.
►
Check the output settings and correct them.
8.4.7 Too Many Boolean Output Fields
The number of Boolean output fields in one CM program is device-dependent.
►
Reduce the Boolean output fields to the device-specific maximum.
8.4.8 Duplicate Boolean Output Field
The inscription of a Boolean output field may not be present more than once in a CM
program.
►
Check the inscription and correct it.
8.4.9 The Bit Number Must Be a Figure between 0 and 14
The property "Bit number" may not lie outside the range of 0 ... 14 for the Boolean
output field function.
►
Check the value that was entered and correct it.
8.4.10 Too Many Numerical Output Fields
The number of numerical output fields in one CM program is device-dependent.
►
Reduce the numerical output fields to the device-specific maximum.
8.4.11 Duplicate Numerical Output Field
The inscription of a numerical output field may not be present more than once in a
CM program.
►
Check the inscription and correct it.