Warranty Information 

CERTIFICATE OF LIMITED WARRANTY:

EXTENT OF COVERAGE: This warranty covers any Fire Chief Furnace FC1500 and FC1700 sold in the United States and Canada.  

This warranty 

is void

 if the Fire Chief Furnace is

 not

 installed, maintained, and operated in accordance with the instructions in the 

owner’s manual and local codes.  

Warranty is also null and void if the unit is used to burn materials for which the unit is not certified by 

the EPA. 

This warranty applies to the original purchaser/owner of the Fire Chief Furnace and is not transferable. Replacement or repair 

parts are warrantied for the remaining period of the original warranty.

All warranty claims must include: 

• Date of purchase

• Model and serial number

• Proof of purchase (dated invoice, bill of sale, cancelled check, or payment record)

• The name / address of the store from which you purchased the furnace

Fire Chief Industries warranties the firebox and cast iron grates to be free of defects in material and workmanship for the liftetime of the 

original purchaser. Intentional misuse or abuse causing burn through of the cast iron components voids all warranties.  Over firing the 

furnace will cause the front face to crack and is not covered by the warranty.  Furthermore, some cosmetic deterioration can be 

expected as the result of normal operation, therefore the physical appearance is not guaranteed to remain unchanged.  The 

manufacturer warranties all electrical components for 1 year and the blower motor for 2 years.  Please be advised that the firebrick and 

door gaskets are excluded from this warranty.

In order to exercise the aforementioned warranty, a certified professional must determine the appliance/part to be defective.  He or she 

must submit a written statement to Fire Chief Industries detailing an assessment of the problem.  This assessment MUST be 

accompanied by substantiating proof of purchase (dated invoice, bill of sale, cancelled check, or payment record), model and serial 

number.  Fire Chief Industries will then authorize repair or replacement as appropriate to the submitted claim.  Fire Chief Industries will 

not honor expenses incurred from any action that was not expressly consented to in writing.  The owner is hereby notified that he or she 

will be obligated to assume liability for removal, reinstallation, shipping, and labor costs involved in servicing/repairing or replacing the 

part or unit.  The merchandise in question must be shipped via PREPAID FREIGHT to Fire Chief Industries.  Fire Chief Industries will 

return the repaired or replacement part to the purchaser on a FREIGHT COLLECT basis.

This warranty will be rendered null and void if this part/unit exhibits symptoms of obvious over-firing, deliberate abuse or negligence, 

improper installation, or is used for commercial purposes.

Finally, Fire Chief Industries will not be responsible for any claim not stated in our warranty nor does any implied warranty extend 

beyond the limits stated above.

Please contact Fire Chief Industries with all pertinent information including daytime phone number and detailed description of the type of 

problem you are having.  Fire Chief Industries technical service personnel will contact you as soon as possible.  Call 1-800-875-4788 or 

mail information to: Fire Chief Industries, 10950 Linpage Place, Saint Louis, MO  63132.

Problem: Cannot hear or detect changes in blower motor speed.

• Your motor has bearings so it

runs smoothly and quietly.

• Refer to information in the manual on page 13 to understand the

operation of the blower motor.

Possible Causes:

Remedies:

15.

Содержание Fire Chief FC1500

Страница 1: ...D BURNING INDOOR FURNACE MODELS FC1500 FC1700 Manufactured by Fire Chief Industries 10950 Linpage Place Saint Louis MO 63132 1 800 875 4788 MADE IN USA Certified to UL391 Sept 2010 CSA B366 1 2014 Rev...

Страница 2: ...This Page Intentionally Blank...

Страница 3: ...that is properly cut and stored to dry will produce more BTUs and higher heat output than wood that has a higher moisture content Wood with higher moisture content will create creosote in the chimney...

Страница 4: ...nsportation Damage Every effort has been made to ensure that your Fire Chief Furnace will arrive in perfect condition Any visible damage should be noted on the freight bill at the time of delivery If...

Страница 5: ...Chimney Fire Warning 13 Power Failure 14 Furnace Diagram with Parts List 15 Grate System Diagram FC1500 16 Grate System Diagram FC1700 16 Blower Motor Assembly Diagram 17 Wiring Diagram 18 Troublesho...

Страница 6: ...or oil fired central furnace listed or certified in accordance with a nationally recognized safety standard and within clearances specified on the nameplate When in a parallel installation the static...

Страница 7: ...t buildup in the furnace causing the blower to short cycle and damage the blower motor and will not be covered under warranty This is not a down draft furnance and not to be installed as one If you do...

Страница 8: ...ion blower using 4 20 bolts and nuts Line up the blower with the pre drilled holes on the backside of the furnace firmly attach with the screws provided 2 Attach blower to the left and right mounting...

Страница 9: ...6 8 sheet metal screws provided 6 Top Panel A 8 Sheet Metal Screw Bottom Panel C Side Panel B Side Panel B 4 Position the assembled filter box on rear of furnace supporting it firmly up to electrical...

Страница 10: ...s of your choice of chimney type for models FC1500 and FC1700 a minimum 6 inch diameter chimney is needed In order to create the most effective draft the chimney size should not exceed 12 inches with...

Страница 11: ...charge When using a brick chimney you must line the entire chimney with stainless steel liner The liner must be 6 for the FC1500 and FC1700 The diameter of the chimney stack should be consistent throu...

Страница 12: ...ESS THAN 6 inches 150mm ON OIL ELECTRIC OR GAS FURNACES DO NOT CONNECT TO A DOWNFLOW FURNACE DO NOT CONNECT DUCTWORK SO THAT A REVERSE FLOW IS POSSIBLE OPERATE THE GAS OIL ELECTRIC FURNACE PERIODICALL...

Страница 13: ...stacked to provide a free flow of air between the logs thus allowing more rapid seasoning of the wood If wood is stored outdoors it should be completely covered year round to protect it from moisture...

Страница 14: ...ated with chemical preservatives in your furnace The combustion of these substances may release harmful toxic gases Do Not Burn Garbage Lawn clippings or yard waste Materials containing rubber includi...

Страница 15: ...urs you are over firing your furnace This type of occurrence is usually symptomatic of heat demands in excess of furnace capacity Contact an authorized professional to determine if your Fire Chief Fur...

Страница 16: ...r desired setting If you are unable to detect or hear the speed change when you move the switch selector to a different setting it doesn t mean the blower motor didn t change speeds Most blower motors...

Страница 17: ...s damaged due to power failure NOTE OVER FIRING OR DELIBERATE ABUSE CAN EASILY BE DETERMINED UPON INSPECTION AND WILL VOID THE WARRANTY Always keep your wood covered year round Dry wood will produce a...

Страница 18: ...WAF 002 WAF 002 7 1 ELECTRICAL CONTROL ASSEMBLY INDOOR WAF IECA WAF IECA 8 1 BLOWER ASSEMBLY FC3SPMOTOR FC3SPMOTOR 8a 1 BLOWER MOTOR FCDD037P FCDD037P 8b 1 BLOWER HOUSING FCBH FCBH 9 1 FILTER BOX KIT...

Страница 19: ...RT 2b 1 ROLLER GRATE EXTENSION BASE SHORT 4 1 FC000 ROLLER GRATE EXTENSION SHORT 5 1 FC000 ROLLER GRATE 6 6 FIRE BRICK FC1700 PARTS LIST ITEM QTY PART DESCRIPTION 1 1 FC000 ROLLER GRATE HANDLE 2 1 ROL...

Страница 20: ...Blower Motor Assembly Diagram 2 1 2 3 17 PARTS LIST PART DESCRIPTION QTY ITEM BLOWER HOUSING ASSEMBLY 1 1 BLOWER MOTOR 1 2 MOTOR CAPACITOR 1 3 2 PART NUMBER FCBH FC3610J370 FC3SPMK...

Страница 21: ...C TRANSFORMER RELAY DRAFT MOTOR ON OFF SWITCH 3 SPEED SWITCH DRAFT BLOWER MOTOR FCDB 3 SPEED BLOWER MOTOR FC3SPMOTOR BLUE MED RED LOW BLACK HI 120V AC POWER SUPPLY WHITE BLACK GREEN BLACK WHITE FCDBSW...

Страница 22: ...ibrates during operation Screw on squirrel cage is not tight Check squirrel cage alignment and position so that it does not drag on the housing during rotation then tighten the screw sufficiently to f...

Страница 23: ...n on page 3 Possible Causes Remedies Excessively long run of stove pipe from furnace to flue Relocate the furnace so the horizontal run does not exceed 5 feet and has a 2 inch rise per foot The run sh...

Страница 24: ...hermostat to call for more heat more often which will initiate the running of the draft blower Consequently the fires will be hotter thereby reducing the accumulation of creosote Install flue gas ther...

Страница 25: ...y There is an obstruction outside chimney such as a tree Flue is located too close to the peak of the roof or does not rise above it to provide the proper draft 9 Problem Odor detected in home during...

Страница 26: ...rmation in the manual relating to the proper installation procedures or contact your local heating and cooling contractor Refer to information in the manual relating to the proper ducting procedures o...

Страница 27: ...e appliance part to be defective He or she must submit a written statement to Fire Chief Industries detailing an assessment of the problem This assessment MUST be accompanied by substantiating proof o...

Страница 28: ...ssing Warranty Claims Please reference this page when requesting Customer Service Customer Information Purchased From Name Dealer Store Street Dealer Store Phone City Date Purchased State Zip Installe...

Отзывы: