GDS-600
– System Installation
67
GDS-600 UPS Battery Backup Time
Issue: V 1.0
For reference only
UPS Brand: Blazer
Models: Blazer 800 V.S. Blazer 1000
Model
Compare Item
Blazer 800
Blazer 1000
Capacity
800VA/480W
1000VA/600W
Battery
12V/9AH x 1 pc
12V/7AH x 2 pcs
Output Waveform
Modified Waveform
Modified Waveform
Weight
6.5 kgs
13.8 kgs
Transfer Time
< 3ms
4-6 ms
Plug into AC Line
Power Switch on & then Battery can
be charged .
Battery is charged when AC line is
plugged in.
DC Fan
No
Yes
GDS 40
32 users
(G1-PWU-2:40V/1.1A, 5V/1.1A)
Total: 43 mins, alert at 39 mins.
Total: 85 mins, alert at 77 mins.
87.8V/0.46A
GDS 64
48 users
(G2-PWU-1: -40V/1.44A, 5V/3.22A)
Total: 33 mins, alert at 30 mins.
97.4V/0.68A, 103.8V/0.75A
Total: 61 mins, alert at 58 mins.
94.5V/0.65A, 104.5V/0.72A
GDS 80
80 users
(G2-PWU-1: -40V/2.53A, 5V/3.8A)
Total: 19 mins, alert at 16 mins.
99.3Vac/1.11A
Total: 36 mins, alert at 33 mins.
97.6V/1.07A