Issue 4.1.1 - October 2014
Optional Cabling
Connect a 6 conductor mounting cord from the
G2-
MSU
to a RJ-25 modular block.
Door Switch (Relay) Connection
One Door Switch (24+-12VDC) may be used
on the GDS-600 system.
2-conductor wiring is required.
Connect the door switch to pins 1 and 6 of the
RJ-11 connector.
Sensor Connection
The Sensor connector on GDS-600 may be
used for the External Sensor input.
The sensor may be configured for normally
open or normally closed operation.
2-conductor wiring is required.
Connect the sensor to pins 2 and 5 of the RJ-
11 connector.
Refer to System Programming Form 39 --
Sensor Assignment.
Paging Connection
The Paging connector on the GDS-600 may
be used for an External Paging input.
2-conductor wiring is required.
Connect the amplifier to pins 3 and 4 of the
RJ-11 connector.
Refer to Illustration Door Switch / Sensor / Paging cabling:
Music on Hold Connection
Connect the (optional) external music source to the external Music" input labeled on the KSU.
Use a 1/8” mini plug to connect the music source to the KSU via an approved line isolation unit.
Door switch/Sensor/Paging cabling