Title Rev.
Page
HMK(P)-081,HMC-081 Ver1.0
52
DC3+’i’
[Name] Cutting after it detects the black mark.
[Format] ASCII DC3 i
Hex 13 69h
Decimal 19 105
[Descript] - The value is not deleted until the next value is changed, even though power off.
If you register the information at SW1,SW2, the black mark detects automatically,
Then it cuts the registerd points.
- Please use the given program - ‘memory swtich setting utility program’.
- Please refer the 2-8)Memory switch.
SUB+’1’
[Name]
Line 1 (Vertical, Horizontal)
[Format] ASCII SUB
1
Hex
1A
31h
Decimal
26
49
[Descript] It chooses the line 1 of vertical, horizontal.
SUB+’2’
[Name]
Line 2 (Vertical, Horizontal)
[Format]
ASCII
SUB
1
Hex
1A
32h
Decimal
26
50
[Descript]
It chooses the line 2 of vertical, horizontal.
SUB+’W’+nL+nH+kL+kH
[Name]
Write (Vertical, Horizontal)
[Format]
ASCII
SUB
W
nL
nH
kL
kH
Hex
1A
57h
nL
nH
kL
kH
Decimal
26
87
nL
nH
kL
kH
[Range]
0
≤
nL+nH×256
≤
640
、
(0
≤
nL
≤
255, 0
≤
nH
≤
3)
0
≤
kL+kH×256
≤
640
、
(0
≤
kL
≤
255, 0
≤
kH
≤
3)
[Descript]
You can write 1 from nL+nH×256 to kL+kH×256.
[Caution]
The range will be ignored, if the range is over.
The data will not be deleted, till you command the data to clear, or power off.
SUB+’C’
[Name]
Clear (Vertical, Horizontal)
[Format]
ASCII
SUB
C
Hex
1A
43h
Decimal
26
67
[Range]
The all of line will be clear as 0 (zero).
[Caution]
Please direct ON/OFF to speed up the process.
It is to write again the data of line.
SUB+’O’
[Name]
ON (Vertical, Horizontal)
[Format]
ASCII
SUB
O
Hex
1A
4Fh
Decimal
26
79
[Descript] It writes the character together.
Содержание HMC-081
Страница 5: ...1 2 Dimension Image1 6 Standard type Title Rev Page HMK P 081 HMC 081 Ver1 0 5 ...
Страница 6: ... Image1 7 Presenter type Title Rev Page HMK P 081 HMC 081 Ver1 0 6 ...
Страница 57: ...Title Rev Page HMK P 081 HMC 081 Ver1 0 57 ...
Страница 61: ...Please ask the person in charge about the sample program Title Rev Page HMK P 081 HMC 081 Ver1 0 61 ...