Title Rev.
Page
HMK(P)-081,HMC-081 Ver1.0
42
GS+’(’+’K’+pL+pH+fn+m (fn=97)
[Name] Operating thermal head partially
[Format] ASCII
GS
(
K
pL
pH
fn
m
Hex
1D
28h
4Bh
pL
pH
fn
m
Decimal 29 40 75 pL pH fn m
[Range]
pL=2, pH=0, fn=97
0
≤
m
≤
2
[Initial Value]
m=0
[Descript]
Set the operation of partial thermal head
[Caution]
This function is effective in case of power capacity is short.
The Second division of electric current (ampere) will be half than first division.
m Partial
operation
0
Initial setting (first division)
1 First
Division
2 Second
Division
GS+’B’+n
[Name]
Reverse printing in black
[Format]
ASCII
GS
B
n
Hex
1D
42h
n
Decimal
29 66 n
[Range]
0
≤
n
≤
255
[Initial Value]
n=0
[Descript]
Reverse printing in black
n=0, standard printing
n=1, reverse printing in black
GS+’H’+n
[Name]
Select the printing position of HRI characters (Barcode)
[Format]
ASCII
GS
H
n
Hex
1D
48h
n
Decimal
29 72 n
[Range]
0
≤
n
≤
3
[Initial Value]
n=0
[Descript]
Select the printing positions of numerical value & characters
n Printing
Position
0 Non
printing
1
Above the barcode
2
Below the barcode
3
Both above & below barcode
Содержание HMC-081
Страница 5: ...1 2 Dimension Image1 6 Standard type Title Rev Page HMK P 081 HMC 081 Ver1 0 5 ...
Страница 6: ... Image1 7 Presenter type Title Rev Page HMK P 081 HMC 081 Ver1 0 6 ...
Страница 57: ...Title Rev Page HMK P 081 HMC 081 Ver1 0 57 ...
Страница 61: ...Please ask the person in charge about the sample program Title Rev Page HMK P 081 HMC 081 Ver1 0 61 ...