Restoring factory defaults
Right-click a device MAC address. Within 60 seconds after powering up the unit,
factory defaults can be restored using UDP Config.
Disconnect the power jack, connect the jumper near the RJ11 sockets, power up
the device and wait for 15 seconds. Then, disconnect the power and disconnect
the jumper. The device is ready in its factory default configuration.
3) WWW interface of the device
To open the WWW interface of the device:
Enter the IP address into a web browser
Click the IP address in UDP Config
Click the underlined IP address in UDP SETUP