background image

4-6

S

TART UP

/ O

PERATION

P/N 0378414G

Excerpt from ANSI / NSF-7:

5.30

Temperature indicating devices

5.30.1

Each refrigerated storage compartment and cabinet

shall have at least one securely mounted temperature indicat-

ing device that clearly displays the air temperature in the 

compartment. A temperature indicating device shall not be

required in beverage coolers or units intended solely for the

storage and/or display of ice cream and other frozen deserts.

5.30.2

The temperature display of a temperature indicating

device shall be visible immediately upon opening a door to

the refrigerated compartment or shall be visible from the

equipment exterior without opening a door to the compart-

ment. The sensing element of the device shall be easily

cleanable and located to reflect the temperature in the

warmest part of the food storage compartment.

Open display refrigerators shall have a temperature indicating

device that is easily cleanable and located to reflect the

warmest part of the food storage compartment. Open display

refrigerators shall include a thermometer and installation

instructions for installing the thermometer in the warmest 

part of the food storage compartment, as determined by the

manufacturer.

Excerpt from 1999 FDA Food Code:

4-204.112

Temperature Measuring Devices.

(A) In a mechanically refrigerated or hot 

FOOD

storage unit, the

sensor of a 

TEMPERATURE MEASURING DEVICE

shall be located to

measure the air temperature in the warmest part of a mechan-

ically refrigerated unit and in the coolest part of a hot 

FOOD

storage unit.

(B) Except as specified in ¶(C) of this section, cold or hot

holding 

EQUIPMENT

used for 

POTENTIALLY HAZARDOUS FOOD

shall

be designed to include and shall be equipped with at least

one integral or permanently affixed 

TEMPERATURE MEASURING

DEVICE

that is located to allow easy viewing of the device’s

temperature display.

(C) Paragraph (B) of this section does not apply to 

EQUIPMENT

for which the placement of a 

TEMPERATURE MEASURING DEVICE

is

not a practical means for measuring the ambient air surround-

ing the 

FOOD

because of the design, type, and use of the

EQUIPMENT

, such as calrod units, heat lamps, cold plates, 

bainmaries, steam tables, insulated 

FOOD

transport containers,

and salad bars.

Important – Please read!

Keep with merchandiser

or give to store manager — do not destroy.

Hussmann P/N 429971A

11/2000

Each installation will be different
depending on how the unit is
stocked, shopping patterns in the
department and ambient conditions
of the store. The suggested loca-
tions provided herein are possible
locations. It is the responsibility of
the purchaser / user to determine
the location within the food storage
area of the unit that best meets the
code requirements above. 

The thermometer may need to be
moved several times to find the
warmest location. Mounting options
include flexible plastic for price tag
molding application, magnet
applied to back of flexible plastic for
steel end wall, and double stick
tape. Tape must not be exposed
after installation. 

Questions about either code should
be addressed to local agencies or
other appropriate officials.

Содержание Impact MWG Series

Страница 1: ...t Delicatessen Dairy and Produce Merchandisers Installation Operation Manual Shipped With Case Data Sheets P N 0378414G Impact Series August 2004 I IM MP PO OR RT TA AN NT T Keep in store for future r...

Страница 2: ...Shelves 4 2 Installing FDA NSF Required Thermometer 4 4 MAINTENANCE Care and Cleaning 5 1 Cleaning Under Merchandisers 5 2 Cleaning Mirrors 5 2 Cleaning Honeycomb Assemblies 5 3 Removing Interior Back...

Страница 3: ...eans that from the time the product is received through storage preparation and display the temperature of the product must be controlled to maximize the life of the product The exterior frames on the...

Страница 4: ...d beneath the merchandiser s support bar SHIPPING BRACES Move the merchandiser as close as possible to its permanent location and then remove all packaging Check for damage before discarding packaging...

Страница 5: ...ure P N 0378414G 1 3 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A Levels Shim Levels NOTE Do not place levels on Display Pans or on Shelves Leveling Single Deck Merchandisers Leveling Multi deck...

Страница 6: ...ttom and up the front of the merchandiser as shown Gasket should cover slots 2 Apply the 15 8 in 41 mm gasket to cover foam to metal gap at rear of case and across the top as shown Be sure to overlap...

Страница 7: ...ut Threaded Rod Glass Front Detail Connecting Canopies of Multi deck Wall Cases Tighten in Order Shown IMPORTANT Do not stretch gasket especially around corners Do not butt gaskets always overlap them...

Страница 8: ...RT Install Splashguard Bracket Position splashguard brackets to the merchandiser and level to the floor Each bracket has a 11 2 in 38 mm slot at the rear of the bracket where it attaches to the mercha...

Страница 9: ...ot to lose the internal joint trims on the upper bumpers 3 Starting at the left end of the line up install the upper bumper starter section first To install a Position internal joint trims so that the...

Страница 10: ...a refrig erated case or cooler during this time This will allow the bumpers and top rails to con tract 10 Go to the right end of the line up and tap the top rail and bumpers to close any gaps 11 Meas...

Страница 11: ...ON SYSTEM BRANCH as this may result in poor refrigeration control and compressor failure Interconnecting piping inside the merchandiser must be located as shown below to allow room for lifting the hin...

Страница 12: ...third of case run load and again after the second third Do not reduce below the case suction line size Case suction lines should enter at the top of the branch line LIQUID LINE May be reduced by one...

Страница 13: ...ST SEQUENCES These merchandisers require defrost cycles for proper operation Refer to the data sheets for application data The Time Clock initiates defrost The evaporator fans continue to circulate ai...

Страница 14: ...circuit the defrost termination thermostats are wired in series ALWAYS CHECK THE SERIAL PLATE FOR COMPONENT AMPERES IDENTIFICATION OF WIRING Leads for all electrical circuits are identified by colore...

Страница 15: ...ng the water seal must be used as part of the drip piping to prevent air leakage or insect entrance Never use two water seals in series in any one drip pipe DOUBLE WATER SEALS IN SERIES WILL CAUSE AN...

Страница 16: ...onnected as shown A drain piping connect kit is required Each merchandiser is supplied with a 2 in 51 mm water seal an adapter a plug and a street ell The street ell and water seal must be installed t...

Страница 17: ...anel 1 Position the lower front panel with the top angled as shown in the illustration below 2 The tabs extending from the upper front panel assembly are designed to fit into the slots on the top of t...

Страница 18: ...fit into the slots on the top of the lower front panel 3 Once the top is positioned lift the panel up and drop it into the grove at the top of the splashguard OPTIONAL Stainless steel splashguards may...

Страница 19: ...a load limit decal Shelf life of perishables will be short if load limit is violated AT NO TIME SHOULD MERCHANDISERS BE STOCKED BEYOND THE LOAD LIMITS INDICATED DO NOT BLOCK HONEYCOMB STOCKING Produc...

Страница 20: ...e individually mounted in 1 in 25 mm increments and have two three or four position brackets permitting shelves to be placed in a flat or down tilt position see illustration Front product stops are re...

Страница 21: ...stration below It is typical of D5 C5 and D6 models Note that other models will have fewer rows of shelves Starting from the left hand bottom section choose the location for the first shelf X 1 Secure...

Страница 22: ...nstalled as support set the next shelf X 4 in the desired location Remove the cap and insert the shelf plug Continue working left to right installing shelves X 5 and X 6 Note Since the location for th...

Страница 23: ...in Multi deck Merchandisers Return Air Grille Shelf Price Tag Molding Suggested Mounting Locations in Single Deck Glass Front Impact Merchandisers Acrylic Package Guard Facing Out Double Stick Tape F...

Страница 24: ...warmest part of a mechan ically refrigerated unit and in the coolest part of a hot FOOD storage unit B Except as specified in C of this section cold or hot holding EQUIPMENT used for POTENTIALLY HAZA...

Страница 25: ...d with a mild detergent and warm water to protect and maintain their attractive finish NEVER USE ABRASIVE CLEANSERS OR SCOURING PADS Interior Surfaces The interior surfaces may be cleaned with most do...

Страница 26: ...SUBMERGE SHELVES IN WATER After cleaning is completed turn on power to the merchandiser CLEANING UNDER MERCHANDISERS Remove splashguards not sealed to floor Use a vacuum with a long wand attachment to...

Страница 27: ...ved from the honeycomb cells before replacing Be careful not to damage the honeycombs Single Deck Cases 1 Using a flat object such as a screw driver compress the honeycomb and remove it from its retai...

Страница 28: ...e lower panel first lift the panel up then pull forward and out 4 Remove the top panel 5 Replace panels in reverse order starting with the top panel 6 After cleaning or servicing the merchandiser reco...

Страница 29: ...ding bottom of motor to fan basket 6 Replace fan motor and blade 7 Lower fan plenum 8 Reconnect fan to wiring harness 9 Turn on power 10 Verify that motor is working and blade is turning in the correc...

Страница 30: ...he rail lamp switch is located on the rail REPLACING LAMP HOLDERS AND END CAPS The Impact lamp holder is designed to snap into the sheet metal of the case The lamp holder has a locking nub which fits...

Страница 31: ...allasts These ballast are located at the top of the merchandiser inside the canopy The switch in the canopy operates both the canopy and the shelf lamps The rail lamp has a separate switch 1 DISCONNEC...

Страница 32: ...1300 Burton St Grand Rapids MI 49507 Phone 1 800 645 3413 Fax 1 800 645 3414 X Ergon 1570 E Northgate P O Box 2102 Irving TX 75062 Phone 1 800 527 9916 NOTE Hussmann Aluminum melts at 1125 F 607 C Ala...

Страница 33: ...ct your Hussmann representative Please include the model and serial number of the product The full product warranty is available from our website www hussmann com Hussmann Corporation Corporate Headqu...

Отзывы: