background image

Medium Temperature

P/N 0378414G

3-3

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483  U.S.A.

INSTALLING SPLASHGUARDS &
LOWER FRONT PANELS

The splashguard and lower front panel are
shipped inside each merchandiser. 

A

FTER

mer-

chandisers have been leveled and joined, and all
drip piping, electrical and refrigeration work has
been completed, install the splashguard and lower
front panel.

NOTE:

Merchandisers with low bases do not

have lower front panels and require only the
installation of splashguards.

To Install Splashguards:

1. Check to be sure that all splashguard brackets

are level with the floor.

2. Position top of splashguard over the top edge

of the bracket as shown below. 

3. Push the lower edge of the splashguard

toward the bottom of the bracket until it snaps
into place.

To Install Lower Front Panel

1. Position the lower front panel with the top

angled as shown in the illustration below.  

2. The tabs extending from the upper front panel

assembly are designed to fit into the slots on
the top of the lower front panel.

3. Once the top is positioned, lift the panel up

and drop it into the grove at the top of the
splashguard.

SEALING SPLASHGUARD TO FLOOR

I

F REQUIRED

by local sanitation codes, or if

desired by the customer, plastic splashguards may
be sealed to the floor using silicone type sealer.
The amount needed will depend on how much
the floor is out of level.

1. Remove all dirt, wax and grease from the area

of the splashguard where adhesion will be
necessary to ensure a secure installation. 

2. Apply a good silicone type sealer along the

bottom of the splashguard. Sealant must be
removed and replaced when servicing.

Silicone-type
Sealer

Splashguard

Lower Front Panel

3.

Tab

Lower Front Panel

1. &
2.

3.

Splashguard

2.

Bracket

Base of
Case

1.

Splashguard

Lower Front Panel

Bracket

Base of
Case

Содержание Impact MWG Series

Страница 1: ...t Delicatessen Dairy and Produce Merchandisers Installation Operation Manual Shipped With Case Data Sheets P N 0378414G Impact Series August 2004 I IM MP PO OR RT TA AN NT T Keep in store for future r...

Страница 2: ...Shelves 4 2 Installing FDA NSF Required Thermometer 4 4 MAINTENANCE Care and Cleaning 5 1 Cleaning Under Merchandisers 5 2 Cleaning Mirrors 5 2 Cleaning Honeycomb Assemblies 5 3 Removing Interior Back...

Страница 3: ...eans that from the time the product is received through storage preparation and display the temperature of the product must be controlled to maximize the life of the product The exterior frames on the...

Страница 4: ...d beneath the merchandiser s support bar SHIPPING BRACES Move the merchandiser as close as possible to its permanent location and then remove all packaging Check for damage before discarding packaging...

Страница 5: ...ure P N 0378414G 1 3 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A Levels Shim Levels NOTE Do not place levels on Display Pans or on Shelves Leveling Single Deck Merchandisers Leveling Multi deck...

Страница 6: ...ttom and up the front of the merchandiser as shown Gasket should cover slots 2 Apply the 15 8 in 41 mm gasket to cover foam to metal gap at rear of case and across the top as shown Be sure to overlap...

Страница 7: ...ut Threaded Rod Glass Front Detail Connecting Canopies of Multi deck Wall Cases Tighten in Order Shown IMPORTANT Do not stretch gasket especially around corners Do not butt gaskets always overlap them...

Страница 8: ...RT Install Splashguard Bracket Position splashguard brackets to the merchandiser and level to the floor Each bracket has a 11 2 in 38 mm slot at the rear of the bracket where it attaches to the mercha...

Страница 9: ...ot to lose the internal joint trims on the upper bumpers 3 Starting at the left end of the line up install the upper bumper starter section first To install a Position internal joint trims so that the...

Страница 10: ...a refrig erated case or cooler during this time This will allow the bumpers and top rails to con tract 10 Go to the right end of the line up and tap the top rail and bumpers to close any gaps 11 Meas...

Страница 11: ...ON SYSTEM BRANCH as this may result in poor refrigeration control and compressor failure Interconnecting piping inside the merchandiser must be located as shown below to allow room for lifting the hin...

Страница 12: ...third of case run load and again after the second third Do not reduce below the case suction line size Case suction lines should enter at the top of the branch line LIQUID LINE May be reduced by one...

Страница 13: ...ST SEQUENCES These merchandisers require defrost cycles for proper operation Refer to the data sheets for application data The Time Clock initiates defrost The evaporator fans continue to circulate ai...

Страница 14: ...circuit the defrost termination thermostats are wired in series ALWAYS CHECK THE SERIAL PLATE FOR COMPONENT AMPERES IDENTIFICATION OF WIRING Leads for all electrical circuits are identified by colore...

Страница 15: ...ng the water seal must be used as part of the drip piping to prevent air leakage or insect entrance Never use two water seals in series in any one drip pipe DOUBLE WATER SEALS IN SERIES WILL CAUSE AN...

Страница 16: ...onnected as shown A drain piping connect kit is required Each merchandiser is supplied with a 2 in 51 mm water seal an adapter a plug and a street ell The street ell and water seal must be installed t...

Страница 17: ...anel 1 Position the lower front panel with the top angled as shown in the illustration below 2 The tabs extending from the upper front panel assembly are designed to fit into the slots on the top of t...

Страница 18: ...fit into the slots on the top of the lower front panel 3 Once the top is positioned lift the panel up and drop it into the grove at the top of the splashguard OPTIONAL Stainless steel splashguards may...

Страница 19: ...a load limit decal Shelf life of perishables will be short if load limit is violated AT NO TIME SHOULD MERCHANDISERS BE STOCKED BEYOND THE LOAD LIMITS INDICATED DO NOT BLOCK HONEYCOMB STOCKING Produc...

Страница 20: ...e individually mounted in 1 in 25 mm increments and have two three or four position brackets permitting shelves to be placed in a flat or down tilt position see illustration Front product stops are re...

Страница 21: ...stration below It is typical of D5 C5 and D6 models Note that other models will have fewer rows of shelves Starting from the left hand bottom section choose the location for the first shelf X 1 Secure...

Страница 22: ...nstalled as support set the next shelf X 4 in the desired location Remove the cap and insert the shelf plug Continue working left to right installing shelves X 5 and X 6 Note Since the location for th...

Страница 23: ...in Multi deck Merchandisers Return Air Grille Shelf Price Tag Molding Suggested Mounting Locations in Single Deck Glass Front Impact Merchandisers Acrylic Package Guard Facing Out Double Stick Tape F...

Страница 24: ...warmest part of a mechan ically refrigerated unit and in the coolest part of a hot FOOD storage unit B Except as specified in C of this section cold or hot holding EQUIPMENT used for POTENTIALLY HAZA...

Страница 25: ...d with a mild detergent and warm water to protect and maintain their attractive finish NEVER USE ABRASIVE CLEANSERS OR SCOURING PADS Interior Surfaces The interior surfaces may be cleaned with most do...

Страница 26: ...SUBMERGE SHELVES IN WATER After cleaning is completed turn on power to the merchandiser CLEANING UNDER MERCHANDISERS Remove splashguards not sealed to floor Use a vacuum with a long wand attachment to...

Страница 27: ...ved from the honeycomb cells before replacing Be careful not to damage the honeycombs Single Deck Cases 1 Using a flat object such as a screw driver compress the honeycomb and remove it from its retai...

Страница 28: ...e lower panel first lift the panel up then pull forward and out 4 Remove the top panel 5 Replace panels in reverse order starting with the top panel 6 After cleaning or servicing the merchandiser reco...

Страница 29: ...ding bottom of motor to fan basket 6 Replace fan motor and blade 7 Lower fan plenum 8 Reconnect fan to wiring harness 9 Turn on power 10 Verify that motor is working and blade is turning in the correc...

Страница 30: ...he rail lamp switch is located on the rail REPLACING LAMP HOLDERS AND END CAPS The Impact lamp holder is designed to snap into the sheet metal of the case The lamp holder has a locking nub which fits...

Страница 31: ...allasts These ballast are located at the top of the merchandiser inside the canopy The switch in the canopy operates both the canopy and the shelf lamps The rail lamp has a separate switch 1 DISCONNEC...

Страница 32: ...1300 Burton St Grand Rapids MI 49507 Phone 1 800 645 3413 Fax 1 800 645 3414 X Ergon 1570 E Northgate P O Box 2102 Irving TX 75062 Phone 1 800 527 9916 NOTE Hussmann Aluminum melts at 1125 F 607 C Ala...

Страница 33: ...ct your Hussmann representative Please include the model and serial number of the product The full product warranty is available from our website www hussmann com Hussmann Corporation Corporate Headqu...

Отзывы: