3-4
D
RIP
P
IPING AND
S
PLASHGUARDS
P/N 0378414G
INSTALLING
OPTIONAL
STAINLESS
STEEL SPLASHGUARDS
The
O
PTIONAL S
tainless steel splashguard is also
shipped inside the merchandiser.
A
FTER
all the
merchandisers have been leveled and joined, and
all drip piping, electrical and refrigeration work
has been completed, install the
O
PTIONAL S
tain-
less steel splashguard and, if appropriate, the
lower front panel.
To Install Splashguards:
1. Check to be sure that all splashguard brackets
are level with the floor.
2. Position top of splashguard over the top edge
of the bracket as shown below.
3. Push the lower edge of the splashguard
toward the bottom of the bracket until it snaps
into place.
To Install Lower Front Panel
1. Position the lower front panel with the top
angled as shown in the illustration below.
2. The tabs extending from the upper front panel
assembly are designed to fit into the slots on
the top of the lower front panel.
3. Once the top is positioned, lift the panel up
and drop it into the grove at the top of the
splashguard.
O
PTIONAL S
tainless steel splashguards may be
sealed to the floor using a vinyl cove base trim.
The size of trim needed will depend on how
much the floor is out of level.
To install the trim to the splashguard:
1. Remove all dirt, wax and grease from the area
of the splashguard where adhesion will be
necessary to ensure a secure installation.
2. Apply a good contact cement to the cove trim
and allow proper drying time according to the
directions supplied with the cement.
3. Install the trim to the splashguard so that it is
lying flush with the floor. D
O NOT SEAL THE
TRIM TO THE FLOOR
.
4.
If required by local health codes
the Cove
Trim may be sealed to the floor, using a sili-
cone type sealer. Sealant must be removed
and replaced when servicing.
Splashguard
Lower Front Panel
3.
Tab
Lower Front Panel
1. &
2.
3.
Splashguard
2.
Bracket
Base of
Case
1.
Splashguard
Lower Front Panel
Bracket
Base of
Case
Cove Trim
Cement