7.10
Section 7
Electrical System and Components
Troubleshooting Guide 3 amp/70 Watt Braking Stator (cont.)
No
Lights
Or
Battery
Charging
(Braking
System
Test)
Test
1. Replace burned out lights.
2. If voltage is
35 volts or more
, stator is
OK. Circuitry on unit that grounds braking
lead is shorted.
If voltage is
less than 35 volts
, test
stator using an ohmmeter (Test 3).
3. With the engine stopped, measure the
resistance from braking lead to ground
using an ohmmeter.
3. If resistance is approximately
0.2-0.4 ohms
, stator is OK.
If resistance is
0 ohms
, stator is shorted.
Replace stator.
If resistance is
infinity ohms
, stator or
lighting lead is open. Replace stator.
Problem
Conclusion
1. Make sure lights are not burned out.
2. Disconnect the braking lead (green) from
the wiring harness.
With engine running in the fast setting,
measure voltage from braking lead to
ground using an AC voltmeter.