9 SHOCK ABSORBER, SWINGARM
When the pressure gauge reaches the specified value, turn
the
Oil reservoir
0
control lever to
Vacuum.
Guideline
0 bar
✓ The vacuum gauge falls to the specified value.
8 mbar
When the vacuum pressure gauge reaches the specified
value, turn the
Oil reservoir
control lever
0
to
Equalize Pressure.
Guideline
1
s
mbar
✓ The pressure gauge drops to the specified value.
0 bar
When the pressure gauge reaches the specified value, turn
the
Damper
control lever
8
to Pressure.
Guideline
0 bar
✓ Oil is pumped into the damper.
✓ The pressure gauge increases to the specified value.
3 bar
When the pressure gauge reaches the specified value, turn
the
Damper
8
control lever to
Vacuum.
Guideline
3 bar
✓ The pressure gauge drops to the specified value.
0 bar
When the pressure gauge reaches the specified value, oper
ate the
On/Off
switch.
Guideline
0 bar
✓ The vacuum pump is switched off.
Slide O-ring
0
to the end of the special tool by the specified
value (distance
f)
minus specified value).
Guideline
10mm
Depth micrometer (T1 07S) (
l!,JI
p. 303)
Slide the floating piston into the reservoir to the shortened
position using the special tool.
83
Содержание F2303P0
Страница 1: ...PIONEERING SINCE 1903 REPAIR MANUAL2016 FS 450 Art no 3403034en Husqvarna MOTORCYCLES ...
Страница 2: ......
Страница 157: ...16 BRAKE SYSTEM Check the foot brake lever for a firm pressure point 155 ...
Страница 281: ...28 SERVICE SCHEDULE 279 ...