4.18
Using the Retardant Spray System
Description
Certain atmospheric conditions (low humidity, high winds, direct sunlight, or hot
weather) may cause wet concrete to dry too fast during the curing and finishing
process. To keep the concrete moist, this machine is equipped with a retardant
spray system consisting of a water tank and two spray nozzles. The operator can
spray the work surface with clean water or water-based retardant as needed.
Requirements
Water/retardant in water tank
Ambient temperature above freezing
Overview
The retardant spray system is controlled by a switch located on the right control
lever handle.
Procedure
Follow the procedure below to operate the retardant spray system.
1. Fill the water tank with clean water or water-based retardant.
2. Open the valve
(a)
.
3. Press and hold the water spray switch
(q)
to activate the pump. The water/
retardant will spray from the two nozzles
(c)
.
NOTICE:
Drain the retardant spray system if the machine will be subject to
temperatures below freezing. Frozen water or frozen retardant may damage the
retardant spray system.
wc_gr010114
a
c
q
Содержание CRT48-33K
Страница 4: ...CALIFORNIA Proposition 65 Warning wc_tx004643en fm 4 Notes ...
Страница 8: ......
Страница 12: ...Table of Contents CRT 48 33K wc_bo5200004710_09TOC fm 12 ...
Страница 22: ...Labels CRT 48 33K 22 wc_si000649gb fm wc_gr0010124 HH GG LL H Q L Q H M BB Z F T S R B D KK N JJ E R BB M NN ...
Страница 32: ...Lifting and Transporting CRT 48 33K 32 wc_tx003110gb fm Notes ...
Страница 36: ...wc_tx002045gb fm 36 Operation CRT 48 33K 4 6 Control Component Locations wc_gr010112 o n m l ...
Страница 101: ...33 Notes 34 Notes ...
Страница 103: ...CRT 48 33K Schematics wc_tx002048gb fm 103 10 Schematics ...
Страница 106: ......