wc_tx002045gb.fm
41
CRT 48-33K
Operation
4.10
Pressure Relief Valves
Locations
The primary pressure relief valve
(a)
is located on the LP cylinder.
The secondary pressure relief valve
(b)
is located on the gas supply hose.
Function
LP system pressure varies depending on the ambient temperature in which the
machine is being operated. Normal LP system pressure will range from about
2.76–12.41 bar (40–180 psi). If the pressure in the LP tank reaches 24.13 bar (350
psi), the primary pressure relief valve
(a)
will open automatically. Excess LP gas is
then released (vented) into the atmosphere. Venting continues until the system
pressure returns to normal.
The secondary pressure relief valve
(b)
is set at 27.58 bar (400 psi). This valve
functions as an emergency backup in case the primary pressure relief valve does
not open. It is rotated downward so that excess LP gas vents away from the
operator.
PR
O
P
A
N
E
a
b
WARNING
Asphyxiation and chemical burn hazards.
If either relief valve is venting, do not inhale or touch released LP gas.
Содержание CRT48-33K
Страница 4: ...CALIFORNIA Proposition 65 Warning wc_tx004643en fm 4 Notes ...
Страница 8: ......
Страница 12: ...Table of Contents CRT 48 33K wc_bo5200004710_09TOC fm 12 ...
Страница 22: ...Labels CRT 48 33K 22 wc_si000649gb fm wc_gr0010124 HH GG LL H Q L Q H M BB Z F T S R B D KK N JJ E R BB M NN ...
Страница 32: ...Lifting and Transporting CRT 48 33K 32 wc_tx003110gb fm Notes ...
Страница 36: ...wc_tx002045gb fm 36 Operation CRT 48 33K 4 6 Control Component Locations wc_gr010112 o n m l ...
Страница 101: ...33 Notes 34 Notes ...
Страница 103: ...CRT 48 33K Schematics wc_tx002048gb fm 103 10 Schematics ...
Страница 106: ......