background image

8

SPEED AND WIRING

The no-load speed of this product is approximately 3,450 
rpm.  This  speed  is  not  constant  and  decreases  under  a 
load  or  with  lower  voltage.  For  voltage,  the  wiring  in  a 
shop is as important as the motor’s horsepower rating. A 
line intended only for lights cannot properly carry a power 
tool motor. Wire that is heavy enough for a short distance 
will  be  too  light  for  a  greater  distance.  A  line  that  can 
support  one  power  tool  may  not  be  able  to  support  two  
or three products.

GROUNDING INSTRUCTIONS

This product must be grounded. In the event of a malfunction 
or breakdown, grounding provides a path of least resistance 
for  electric  current  to  reduce  the  risk  of  electric  shock. 
This  product  is  equipped  with  an  electric  cord  having  an  
equipment-grounding conductor and a grounding plug. The 
plug must be plugged into a matching outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.
Do not modify the plug provided. If it will not fit the outlet, 
have the proper outlet installed by a qualified electrician. 

WARNING: 

Improper  installation  of  the  grounding  plug  is  able  to   
result  in  a  risk  of  electric  shock.  When  repair  or   
replacement of the cord is required, do not connect the 
grounding wire to either flat blade terminal. The wire with 
insulation having an outer surface that is green with or 
without yellow stripes is the grounding wire. 

Check with a qualified electrician or service personnel if the 
grounding instructions are not completely understood, or if 
in doubt as to whether the product is properly grounded.
Repair or replace a damaged or worn cord immediately.
This  product  is  for  use  on  a  nominal  10  volt  circuit  and 
has a grounding plug similar to the plug illustrated in figure 
1. Only connect the product to an outlet having the same 
configuration as the plug. Do not use an adapter with this 
product.

 

ELECTRICAL

Fig. 1 

EXTENSION CORDS

Use only 3-wire extension cords that have 3-prong grounding 
plugs and 3-pole receptacles that accept the product’s plug. 
When using a power tool at a considerable distance from 
the power source, use an extension cord heavy enough to 
carry the current that the product will draw. An undersized 
extension cord will cause a drop in line voltage, resulting in 
a loss of power and causing the motor to overheat. Use the 
chart provided below to determine the minimum wire size 
required in an extension cord. Only round jacketed cords 
listed by Underwriter’s Laboratories (UL) should be used.

**Ampere rating (on product data plate)

 

 

0-.0 

.1-3.4 

3.5-5.0  5.1-7.0  7.1-1.0   1.1-16.0

Cord Length   

 Wire Size (A.W.G.)

  5' 

16 

16 

16 

16 

14 

14

  50' 

16 

16 

16 

14 

14 

1

  100' 

16 

16 

14 

10 

**Used on 12 gauge - 20 amp circuit.

NOTE: AWG = American Wire Gauge

When working with the product outdoors, use an extension 
cord that is designed for outside use. This is indicated by the  
letters “WA” on the cord’s jacket.
Before  using  an  extension  cord,  inspect  it  for  loose  or  
exposed wires and cut or worn insulation.

WARNING:

Keep  the  extension  cord  clear  of  the  working  area. 
Position the cord so that it will not get caught on lumber, 
tools, or other obstructions while you are working with 
a power tool. Failure to do so can result in serious per-
sonal injury.

WARNING:

Check  extension  cords  before  each  use.  If  damaged 
replace immediately. Never use the product with a dam-
aged cord since touching the damaged area could cause 
electrical shock resulting in serious injury.

ELECTRICAL CONNECTION

This product is powered by a precision-built electric motor. 
It should be connected to a 

power supply that is 120 volts, 

60 Hz, AC only (normal household current). Do not oper-
ate this product on direct current (DC). A substantial voltage 
drop will cause a loss of power and the motor will overheat. 
If the product does not operate when plugged into an outlet, 
double check the power supply.

GroundinG Pin

120V Grounded outlet

Содержание H150PL

Страница 1: ...RNING To reduce the risk of injury the user must read and understand the operator s manual before using this product Thank you for buying a Husky product OPERATOR S MANUAL 1 5 Gallon PORTABLE Air Comp...

Страница 2: ...not equipped and should not be used to supply breathing quality air Additional equip ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing...

Страница 3: ...l be required in some environments For example the working area may in clude exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing pro...

Страница 4: ...at pressure greater than 125 psi Risk of Injury Do not direct air stream at body Do not used compressed air for breathing Do not carry while painting If connected to a circuit protected by fuses use...

Страница 5: ...nd perform its intended function Check for alignment of moving parts bind ing of moving parts breakage of parts mounting and any other conditions that may affect its operation A guard or other part th...

Страница 6: ...s that involve your safety Do not spray flammable liquid in a confined area Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as...

Страница 7: ...efore beginning power tool operation always wear safety goggles or safety glasses with side shields and when needed a full face shield We recommend Wide Vision Safety Mask for use over eyeglasses or s...

Страница 8: ...ug Do not use an adapter with this product Electrical Fig 1 Extension Cords Useonly3 wireextensioncordsthathave3 pronggrounding plugs and 3 pole receptacles that accept the product s plug When using a...

Страница 9: ...Overload Switch Automatically shuts off the compressor if the temperature of the electric motor exceeds a predetermined limit glossary of terms Air Filter Porous element contained within a metal or pl...

Страница 10: ...Oil Free Gauges 2 in diameter Input 120 V 60 Hz AC only 8 5 Amps Net Weight 33 0 lbs 80 1 0 0 8 4 120 80 1 0 0 12 P U S H R E ET S D i s c o n n e c t A l w a y s A i r S u p p l y D i s c o n n e c...

Страница 11: ...an be detached from the air compressor and used on a tool belt FEATURES ASSEMBLY UNPACKING This product requires assembly n Carefully remove the product and any accessories from the box Make sure that...

Страница 12: ...you care less Remember that a careless fraction of a second is sufficient to inflict serious injury WARNING Always wear safety goggles or safety glasses with side shields when operating power tools Fa...

Страница 13: ...poses listed below Operating some light duty air powered tools Inflating tires air beds sports equipment etc Inflation accessories sold separately tURNING THE AIR COMPRESSOR On OFF See Figure 5 n Turn...

Страница 14: ...e clockwise until tightly closed TO OPEN TILT TANK DRAIN VALVE WARNING Always disconnect the air supply and power supply before making adjustments servicing a tool or when a tool is not in use operati...

Страница 15: ...Any continued loss of air after releasing the ring indicates a problem with the pressure relief valve Discontinue use and seek service before continued use of the air compressor warning If air leaks...

Страница 16: ...n blowing dust If operation is dusty also wear a dust mask WARNING Always release all pressure disconnect from power sup ply and allow unit to cool to the touch before cleaning or making repairs on th...

Страница 17: ...onnect other electrical appli ances from circuit or operate compres sor on its own branch circuit Check for proper gauge wire and cord length Take compressor to service center Push Button Overload pro...

Страница 18: ...n this operator s manual This warranty does not apply to any damage to the One World Technologies Inc product that is the result of improper maintenance or to any One World Technologies Inc product th...

Страница 19: ...NOTES...

Страница 20: ...pair parts always give the following information MODEL NUMBER SERIAL NUMBER H150PL OPERATOR S MANUAL 1 5 Gallon PORTABLE Air Compressor H150PL WARNING Some dust created by power sanding sawing grindin...

Отзывы: