background image

13

100

120

140

160

80

60

40

6

4

PRESSURE GAUGE

2

0

8

10
12

14

100

120

140

160

80

60

40

6

4

PRESSURE GAUGE

2

0

8

10

12

14

WARNING: 

Always ensure the switch is in the 

OFF position and the 

regulator pressure gauge reads zero before changing air 
tools or disconnecting the hose from the air outlet. Failure 
to do so could result in possible serious personal injury.

  Rotate regulator knob clockwise to open air flow.

  Connect the power cord to the power supply.

  Turn the power switch

 to 

AUTOMATIC position.

  Rotate pressure regulator knob to desired line pressure. 

Turning the knob clockwise increases air pressure at the 
outlet; turning counterclockwise reduces air pressure at 
the outlet.

  Following all safety precautions in this manual and the 

manufacturer’s instructions in the air tool manual, you 
may now proceed to use your air powered tool.

Fig. 5

Fig. 6

oFF

autoMatiC

oFF / autoMatiC

QuiCK-ConneCt 

air FittinG

1/4 in.QuiCK  

CouPler

OPERATION

APPLICATIONS

Air compressors are utilized in a variety of air system applica-
tions. Match hoses, connectors, air tools, and accessories 
to the capabilities of the air compressor.
You may use this tool for the purposes listed below:

 

Operating some light duty air powered tools

 

Inflating  tires,  air  beds,  sports  equipment,  etc.  
(Inflation accessories sold separately)

TURNING THE AIR COMPRESSOR ON/OFF

See Figure 5.

  Turn the power switch to the 

AUTOMATIC position to 

power the compressor on.

  To turn the air compressor off, turn the power switch to 

the 

OFF position.

USING THE AIR COMPRESSOR

See Figures 5 - 6.

  Ensure power switch is in the 

OFF position and air com-

pressor is unplugged.

  If  not  already  installed,  attach  hose  to  compressor  as 

previously instructed.

  Attach 1/4 in. NPT male connector fitting of tool and into 

female coupler end of air hose.

WARNING:

Your  tool  may  require  more  air  consumption  than  this 
air compressor is capable of providing. Check the tool 
manual to avoid damage to the tool or risk of personal 
injury.

  If using an inflation accessory, control the amount of air 

flow with the pressure regulator knob. Turning the knob 
fully  counterclockwise  will  completely  stop the  flow  of 
air.

 

NOTE:  Always  use  the  minimum  amount  of  pressure 
necessary for your application. Using a higher pressure 
than needed will drain air from the tank more rapidly and 
cause the unit to cycle on more frequently.

  When  finished,  always  drain  the  tank  and  unplug  the 

unit. Never leave the unit plugged in and/or running unat-
tended.

 

(See page 15 for draining instructions.)

Содержание H150PL

Страница 1: ...RNING To reduce the risk of injury the user must read and understand the operator s manual before using this product Thank you for buying a Husky product OPERATOR S MANUAL 1 5 Gallon PORTABLE Air Comp...

Страница 2: ...not equipped and should not be used to supply breathing quality air Additional equip ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing...

Страница 3: ...l be required in some environments For example the working area may in clude exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing pro...

Страница 4: ...at pressure greater than 125 psi Risk of Injury Do not direct air stream at body Do not used compressed air for breathing Do not carry while painting If connected to a circuit protected by fuses use...

Страница 5: ...nd perform its intended function Check for alignment of moving parts bind ing of moving parts breakage of parts mounting and any other conditions that may affect its operation A guard or other part th...

Страница 6: ...s that involve your safety Do not spray flammable liquid in a confined area Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as...

Страница 7: ...efore beginning power tool operation always wear safety goggles or safety glasses with side shields and when needed a full face shield We recommend Wide Vision Safety Mask for use over eyeglasses or s...

Страница 8: ...ug Do not use an adapter with this product Electrical Fig 1 Extension Cords Useonly3 wireextensioncordsthathave3 pronggrounding plugs and 3 pole receptacles that accept the product s plug When using a...

Страница 9: ...Overload Switch Automatically shuts off the compressor if the temperature of the electric motor exceeds a predetermined limit glossary of terms Air Filter Porous element contained within a metal or pl...

Страница 10: ...Oil Free Gauges 2 in diameter Input 120 V 60 Hz AC only 8 5 Amps Net Weight 33 0 lbs 80 1 0 0 8 4 120 80 1 0 0 12 P U S H R E ET S D i s c o n n e c t A l w a y s A i r S u p p l y D i s c o n n e c...

Страница 11: ...an be detached from the air compressor and used on a tool belt FEATURES ASSEMBLY UNPACKING This product requires assembly n Carefully remove the product and any accessories from the box Make sure that...

Страница 12: ...you care less Remember that a careless fraction of a second is sufficient to inflict serious injury WARNING Always wear safety goggles or safety glasses with side shields when operating power tools Fa...

Страница 13: ...poses listed below Operating some light duty air powered tools Inflating tires air beds sports equipment etc Inflation accessories sold separately tURNING THE AIR COMPRESSOR On OFF See Figure 5 n Turn...

Страница 14: ...e clockwise until tightly closed TO OPEN TILT TANK DRAIN VALVE WARNING Always disconnect the air supply and power supply before making adjustments servicing a tool or when a tool is not in use operati...

Страница 15: ...Any continued loss of air after releasing the ring indicates a problem with the pressure relief valve Discontinue use and seek service before continued use of the air compressor warning If air leaks...

Страница 16: ...n blowing dust If operation is dusty also wear a dust mask WARNING Always release all pressure disconnect from power sup ply and allow unit to cool to the touch before cleaning or making repairs on th...

Страница 17: ...onnect other electrical appli ances from circuit or operate compres sor on its own branch circuit Check for proper gauge wire and cord length Take compressor to service center Push Button Overload pro...

Страница 18: ...n this operator s manual This warranty does not apply to any damage to the One World Technologies Inc product that is the result of improper maintenance or to any One World Technologies Inc product th...

Страница 19: ...NOTES...

Страница 20: ...pair parts always give the following information MODEL NUMBER SERIAL NUMBER H150PL OPERATOR S MANUAL 1 5 Gallon PORTABLE Air Compressor H150PL WARNING Some dust created by power sanding sawing grindin...

Отзывы: